Thermistors

5. Thermistors
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1
Release the outdoor
temperature thermistor
the slit.
2
Remove the 5 screws.
3
Lift up the right side
panel to unfasten the 2
hooks.
4
Remove the right side
panel.
5
Cut the clamp.
6
Pull out the outdoor
heat exchanger
thermistor and liquid
pipe thermistor.
14
disassembling work.
Procedure
Slit
Back view
Hook
Hook
Liquid pipe thermistor
Thermistor harness
Outdoor temperature
thermistor holder
Right side panel
Clamp
Outdoor heat
exchanger
thermistor
Points
 When reassembling, pass
the outdoor temperature
thermistor through the top U-
bend of the outdoor heat
exchanger.
(R26037)
 When reassembling, make
sure that the 2 hooks are
securely fastened.
Hook
(R26039)
 Be careful not to lose the clip
for the thermistor.
(R26041)
Removal Procedure
Si002154E
(R26038)
(R26040)
Clip