Overviews of Setting Order

The processing flow for using this product is roughly divided into 3 categories as shown in the figure
below.
Initialization processing
Waveform judgment setting
Data acquisition
End processing
1.
Acquisition condition setting
Perform the settings related to the entire operation of the digitizer.
Set digitizer operation mode, event controller, abort factor, event notification, filterting of digital signal
and so on.
< Horizontal axis setting >
It is settings concerning the time axis of the digitizer.
It performs settings of sampling mode, reference clock source,, sampling clock source, sample rate,
acquisition record length, acquisition record times, trigger point (duty ratio) and so on.
< Vertical axis setting >
It is settings of each channel of the digitizer.
It performs settings of input range, offset, impedance, coupling, band width, probe attenuation rate
and so on.
< Trigger setting >
It is settings concerning the pre-trigger and the post-trigger.
It performs settings of trigger type, the direction of the edge, level voltage, hysteresis, settling
times, hold off time, delay time and so on.
<Waveform judgment setting>
It is settings when the digitizer is used in the waveform judgment instrument mode.
2. Operation start
Start the digitizer operation after setting acquisition conditions.
It is possible to generate a signal and stop the operation by a software command.
The state of the digitizer can be confirmed by acquiring the status, the number of samples, the number
of records etc.
DIG-100M1002-PCI
Operation start
Common setting
Horizontal axis setting
Vertical axis setting
Trigger setting
Waveform judgment setting
4. Functions