Download Print this page

DeWalt DCL079 Original Instructions Manual page 5

Hide thumbs Also See for DCL079:

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
*Date code 201811475B or later
**Date code 201536 or later
Batteries
Cat #
V
DC
DCB546
18/54
DCB547
18/54
DCB548
18/54
12.0/4.0
DCB181
18
DCB182
18
DCB183/B
18
DCB184/B
18
DCB185
18
DCB187
18
DCB189
18
*Date code 201811475B or later
**Date code 201536 or later
Residual Risks
In spite of the application of the relevant safety regulations
and the implementation of safety devices, certain residual risks
cannot be avoided. These are:
Impaired vision when looking diretly into light
Burns from touching a hot surface
Chargers
D
WALT chargers require no adjustment and are designed to be
e
as easy as possible to operate.
Electrical Safety
The electric motor has been designed for one voltage only.
Always check that the battery pack voltage corresponds to the
voltage on the rating plate. Also make sure that the voltage of
your charger corresponds to that of your mains.
Your D
WALT charger is double insulated in
e
accordance with EN60335; therefore no earth wire
is required.
If the supply cord is damaged, it must be replaced by a
specially prepared cord available through the D
service organisation.
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
Connect the brown lead to the live terminal in the plug.
Connect the blue lead to the neutral terminal.

WARNING: No connection is to be made to the
earth terminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 3 A.
Using an Extension Cable
An extension cord should not be used unless absolutely
necessary. Use an approved extension cable suitable for
the power input of your charger (see Technical Data). The
Weight (kg) DCB104
DCB107
Ah
6.0/2.0
1.05
60
9.0/3.0
1.46
75*
1.44
120
1.5
0.35
22
4.0
0.61
60/40**
2.0
0.40
30
5.0
0.62
75/50**
1.3
0.35
22
3.0
0.54
45
4.0
0.54
60
WALT
e
Chargers/Charge Times (Minutes)
DCB112
DCB113
DCB115
270
170
140
90
420
270
220
135*
540
350
300
180
70
45
35
22
185
120
100
60
90
60
50
30
240
150
120
75
60
40
30
22
140
90
70
45
185
120
100
60
minimum conductor size is 1 mm
is 30 m.
When using a cable reel, always unwind the cable completely.
Important Safety Instructions for All Battery
Chargers
SAVE THESE INSTRUCTIONS: This manual contains important
safety and operating instructions for compatible battery
chargers (refer to Technical Data).
Before using charger, read all instructions and cautionary
markings on charger, battery pack, and product using
battery pack.

WARNING: Shock hazard. Do not allow any liquid to get
inside charger. Electric shock may result.

WARNING: We recommend the use of a residual current
device with a residual current rating of 30mA or less.

CAUTION: Burn hazard. To reduce the risk of injury,
charge only D
WALT rechargeable batteries. Other types of
e
batteries may burst causing personal injury and damage.

CAUTION: Children should be supervised to ensure that
they do not play with the appliance.
NOTICE: Under certain conditions, with the charger
plugged into the power supply, the exposed charging
contacts inside the charger can be shorted by foreign
material. Foreign materials of a conductive nature such
as, but not limited to, steel wool, aluminum foil or any
buildup of metallic particles should be kept away from
charger cavities. Always unplug the charger from the
power supply when there is no battery pack in the cavity.
Unplug charger before attempting to clean
DO NOT attempt to charge the battery pack with any
chargers other than the ones in this manual. The charger
and battery pack are specifically designed to work together.
These chargers are not intended for any uses other than
charging D
WALT rechargeable batteries. Any other uses
e
may result in risk of fire, electric shock or electrocution.
Do not expose charger to rain or snow.
English
DCB118
DCB132
DCB119
60
90
X
75*
135*
X
120
180
X
22
22
45
60/40**
60
120
30
30
60
75/50**
75
150
22
22
X
45
45
90
60
60
120
; the maximum length
2
3

Advertisement

loading