Removal of Electrical Box / PCB
Step
10
Unfasten the hook, and
remove the right side
panel.
Pull out the terminals
11
from the terminal board
except the earth wire.
12
Remove the screw and
release the earth wire.
13
Disconnect the
connector [S80].
8
Procedure
Hook
White
Red
Black
Reactor
Right
side
panel
(R14502)
1 : black, upper
2 : white, lower
3 : red, upper
: green, lower
Earth wire
(R17482)
Earth wire
(R17483)
[S80]: four way valve coil
[S80]
The harness of the four way
valve coil and the harness of
the reactor cross each other.
(R14505)
Si001161
Points