VersiCharge™ AC series – Technical data
Features and functions
Charging mode
Vehicle connection
AC power output
Mounting options
Touch Button
Charging status LEDs
Communication status LEDs
Parent/child Network:
Load management
Communication
Interfaces
User authentication
Configuration
Back-end protocol
Software upgrade
Electrical design
Power supply voltage
Rated current settings (A)
Cross wire section
Network type
Energy metering
Ground fault protection
Over voltage protection
Over current protection
Operating altitude
General design
Environmental rating
Dimensions (HxWxD)
Weight
Ambient conditions
Colors
Certificates and standards
cUL listed
EMC
Max.
current Model number
40 A
Residential
Smart
version
48 A
40 A
Child
48 A
Commercial
40 A
versions
Parent
40 A
48 A
48 A
Back-end protocol: OCPP 1.6, upgradeable to OCPP 2.0.1
Data plans for chargers: Siemens offers chargers with data plans for customer convenience. See table below for data plans.
Description
AT&T 1 year data plan, 2GB capped monthly bandwidth (supports ONE Parent charger).
AT&T 1 year data plan, 5GB capped monthly bandwidth (supports ONE parent charger and up to 9
commercial child chargers). This is a yearly fee that Siemens will bill direct after year one.
Extended Warranty per Level 2 charger - 1 additional year, No In/Out services
Extended Warranty per Level 2 charger - 2 additional years, No In/Out services
Level 2
J1772 plug with 20 ft cable, 40/48 A / integrated cable management
Single phase up to 9.6 kW (40A) - requires a 50A breaker, or 11.5kw (48A) - requires a 60A breaker
Wall and post mounting, see accessories
Time delay, return to max power level, reset ground fault
Power, time delay, charging state, reduced power level, authentication, cold start
Connected / not connected during operation, signal strength during commissioning
Connects up to 9 child units by Wi-Fi (100 ft line of sight)
via OCPP or via Modbus
Ethernet, Wi-Fi, Modbus RS-485, Modbus TCP/IP, for parent units additionally LTE, WCDMA
RFID (local Whitelist, MiFare)
via Siemens mobile app or the PC Configuration tool
OCPP 1.6, upgrade-able to OCPP 2.0.1
over the air (OTA)
Single phase: 208 V / 240 V AC, 60 Hz
12, 16, 24, 32, 40, 48
Single phase: 8 AWG / 6 AWG (90° C rated wire)
Single phase / split phase
Embedded metering, +/- 1% accuracy
20 mA
Under voltage: 167 V (min. 80 V) / over voltage: 267 V (max. 275 V)
Current +10% above configured threshold, min. +2A, 5 seconds
9,840 ft
Indoor and Outdoor, NEMA 4, IK 8
16.10 in x 7.09 in x 3.78 in
17 lbs
Operating temperature: -31°F - +122°F, Storage Temp.: -40°F to +140°F, 98% non condensing
Silver Metallic (Pantone 10077), Black holster
according to UL 1998, UL 991, UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA C22.2 No.281.1/
NMX-J-668-1, UL 2231-2/CSA C22.2 No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2
No.282/NMX-J-678-ANCE
FCC Part 15.247, FCC Part 15B, FCC Part 15C
Wi-Fi and
Ethernet
8EM1312-4CF18-0FA3
8EM1312-5CF18-0FA3
8EM1310-4CF14-0GA0
8EM1310-5CF14-0GA0
8EM1310-4CF14-1GA1
8EM1310-4CF14-1GA2
8EM1310-5CF14-1GA1
8EM1310-5CF14-1GA2
VersiCharge™ AC Electric vehicle charging station
Modbus
RFID
Embedded
RTU / TCP
identification
metering
Catalog Number
P3R77992000784
P3R77992000800
US2:VCEXWAR1YR
US2:VCEWAR2YR
LTE
Installed
WCDMA
SimCard