ADT K5309V2 User Manual

ADT K5309V2 User Manual

Adt security services k5309v2 user guide

Advertisement

Meets ADT Security Services Triple Standards
Requirements:
C
US
LISTED
Standards for Security and Fire
Standard for False Alarm Reduction
California State Fire Marshal Approval
7 167-0495:110
K5309V2 1/02
Š
1
Model SASW3000EN

Advertisement

Table of Contents
loading

Summary of Contents for ADT K5309V2

  • Page 1 Meets ADT Security Services Triple Standards Requirements: LISTED Standards for Security and Fire Standard for False Alarm Reduction California State Fire Marshal Approval 7 167-0495:110 K5309V2 1/02 Š Model SASW3000EN...
  • Page 2 PROPER INTRUSION PROTECTION For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Customer Care Center in the event that the telephone lines are out of order (alarm signals are normally sent over...
  • Page 3: Table Of Contents

    System Overview ... 5 Introduction ... 5 System Basics ... 5 Using the Voice Message Center ... 7 About The Touchpads ... 8 General Information... 8 Functions of the Touchpads ... 10 Entry/Exit Delays ... 12 Exit Delay... 12 Entry Delay... 12 Exit Alarms ...
  • Page 4 Table of Contents Macro Key Programming & Usage... 23 About Macro Keys... 23 Example of Macro Programming ... 24 Using a Programmed Macro Key... 24 Using Device Commands ... 25 Paging Feature ... 26 About Automatic Paging ... 26 About Manual Paging... 27 Latch Key Paging ...
  • Page 5 Congratulations on your ownership of an ADT Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, and millions of premises are protected by ADT systems. This system provides: Three forms of protection: burglary, fire* and emergency.
  • Page 6 Zones and Partitions The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.). Zone numbers are displayed at the touchpad when an alarm or trouble condition occurs on a sensor. Partitions provide two independent areas of protection, with each partition containing a group of zones that can be armed and disarmed without affecting other zones or users.
  • Page 7 Phone Access If included, a phone module permits you to access the system via a touch-tone phone, either on-premises or by call-in when away. When you call in, the phone module announces system status over the telephone, and you can arm/disarm the system and perform most function commands remotely using the telephone keys.
  • Page 8: System Overview

    Your touchpads allow you to control all system functions and feature the following: A telephone style (digital) keypad Liquid Crystal Display (LCD) which shows the nature and location of all occurrences Built-in sounder which will sound during alarms and troubles. The sounder also "beeps"...
  • Page 9: English Display Touchpad

    AWAY: All burglary zones, interior and perimeter, are armed. Perimeter burglary zones, such as STAY: protected windows and doors, are armed. Entry delay is turned off: INSTANT: Lit with STAY = Instant mode Lit with AWAY = Maximum mode BYPASS: This appears when one or more burglary protection zones have been bypassed.
  • Page 10 NOTE: The functions printed directly on the keys indicate their primary purpose (most require entry of a security code first); the functions printed under some keys (shown in brackets in the list below) indicate an alternate function available on voice touchpads only.
  • Page 11 Custom English Display Voice Touchpad (shown without swing-down front door) IMPORTANT! • When entering codes and commands, sequential key depressions must be made within 10 seconds of one another. If 10 seconds elapse without a key depression, the entry will be aborted and must be repeated from its beginning. Be sure to observe this precaution when performing any of the procedures in this manual.
  • Page 12: Exit Delay

    Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. You must disarm the system (simply enter your security code) before the entry delay period ends, or an alarm will occur. The touchpad beeps during the entry delay period, reminding you to disarm the system.
  • Page 13: Exit Alarms

    Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message "CANCELED ALARM"...
  • Page 14: Arming The System

    Used when you want to arm the system with persons staying inside (or if you have pets that are moving throughout the premises). The perimeter sensors are armed, but interior sensors are left disarmed. Exit delay begins (you can leave through the entry/exit door, if desired). An alarm sounds immediately if any protected perimeter window or non-entry/exit door is opened.
  • Page 15: Arming Commands

    Before arming, close all perimeter doors and windows and make sure the Ready to Arm message is displayed. Modes of Arming Mode Press these keys… Stay security code + [3] (STAY) Night-Stay security code + [3] + [3] Instant security code + [7] (INSTANT) Away security code + [2] (AWAY) Quick Arming...
  • Page 16: Single-Button "Step" Arming

    The “A”, “B”, “C”, and/or “D” keys on your touchpad may have been programmed for single-button arming. Note that while it will not be necessary to use a security code for arming, a security code must always be used to disarm the system. If Single-Button Arming is programmed: A function key has been assigned to a specific type of arming: STAY mode, Night- STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming paragraph).
  • Page 17 Your system may be equipped with a keyswitch for use when arming and disarming. Red and green lights on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones).
  • Page 18 The OFF key is used to disarm the system, silence alarm and trouble sounds, and clear alarm memories. IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the touchpad will beep rapidly upon your entering, indicating that an alarm has occurred during your absence.
  • Page 19 Use t his key when you want to arm your system with one or more zones intentionally unprotected. Vent Zones: Your system may have certain windows set as “vent” zones, which are automatically bypassed if left open when arming the system (you do not need to manually bypass them).
  • Page 20: Quick Bypass

    If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. This feature is useful if, for example, you routinely leave certain windows open when arming at night. + 6 + [#] (Security Code) BYPASS In a few moments, all open zones will be displayed...
  • Page 21: Viewing Current Date And Time

    The system lets you view its time and date setting. +[#] + [6] [3] (Security Code) OR, press the function key (A, B, C, or D) for viewing current date and time, if programmed. A typical time/date display is shown. The display will remain on for about 30 seconds.
  • Page 22: Panic Keys

    Your system may have been programmed to use special keys to manually activate emergency (panic) functions as follows: This Function Sends this signal* Silent Alarm silent alarm Audible Alarm audible alarm Personal Alarm auxiliary alarm Fire Alarm fire alarm *All panic functions send signals to the Customer Care Center, if connected. To activate a Panic Function: Press and hold down for at least 2 seconds whichever lettered key on the touchpad has been programmed for...
  • Page 23 The “A”, “B”, “C” or “D” keys can be used to automatically activate a series of commands of up to 16 keystrokes, if programmed for this function. These keystrokes, as a group, are called “macros” and are stored in the system's memory. Typical macro functions can include: - Arming sequences: STAY, Night-STAY, INSTANT, or AWAY - Bypassing particular zone(s)
  • Page 24 The touchpad beeps to acknowledge your input and displays the command you entered (followed by “F”). 4. Enter the next command, followed by press/holding the “D” key for at least two seconds. The touchpad beeps and displays the keystrokes entered so far. 5.
  • Page 25 Your system may be set up so that it can control certain lights or other devices. Some devices may be automatically turned on or off by the system. You may be able to override automatically controlled devices using the commands described below. Some devices can be manually turned on or off using the commands described below.
  • Page 26 Your system may be set up to automatically send alert messages to a pager as certain conditions occur in your system. The following events can be programmed by your installer to be sent to the pagers: † arming, disarming , alarms, and trouble conditions. († reports when arming/disarming from a touchpad using a security code;...
  • Page 27 Your system may be set up so you can manually send a message to up to four pagers. Your installer programs the paging function key and the pager phone numbers. Pressing the paging keys sends the message This message could mean “call home”, “call your office”, or any other prearranged meaning.
  • Page 28 Your system lets you assign up to 45 different security codes for use by other users. Only the System Master and Partition Masters can assign user codes to users. Users are identified by 2-digit user numbers 03-49 and are pre-assigned to either partition 1 or partition 2 (users 01-02 are reserved).
  • Page 29 The following lists the various command strings for adding user codes and attributes. Refer to the User Setup chart at the back of this manual for factory assignments of user attributes and to keep a record of user programming. NOTE: Partition Master codes apply only to those user numbers previously assigned (by the system master/installer) to the partition master’s partition.
  • Page 30 Each touchpad is assigned a default partition for display purposes, and will show only that partition's information. If the user is authorized, a touchpad in one partition can be used to perform system functions in the other partition by using the GOTO command. Refer to the GOTO section.
  • Page 31 If the user is authorized, a touchpad in one partition can be used to perform system functions in the other partition by using the GOTO command. You must use a Custom English touchpad to access another partition. Touchpads automatically return to their original partition after 2 minutes with no touchpad activity.
  • Page 32 Your system may have been set up to use a common zone, which is Ask your installer if a an area shared by users of both partitions, such as a foyer or lobby. "common zone" was If so, please note the following: assigned.
  • Page 33: Using Device Commands

    The system provides up to 16 end-user schedules (programmable by master/installer only), which can be used to control various types of events. Each schedule causes a defined event to start and stop (when appropriate) at a specified time. Schedules can be set to automatically repeat at various intervals. Schedules can be set for random starting, if desired.
  • Page 34 5. For event number “02,” enter the access group number. Otherwise, this prompt is skipped. Press [ ] to continue to the “Start” prompt below. 6. For event numbers “03-07,” enter the partition number to be armed or disarmed. 0 = arm all; 1 = partition 1; 2 = partition 2; 3 = arm common Otherwise, this prompt is skipped.
  • Page 35 The system records various events in a history log, which can be viewed by the master user using a Custom English Display touchpad. The Event Log holds up to 100 events. Events are displayed in chronological order, from most recent to oldest. When the log is full, the oldest event is replaced by the logging of any new event.
  • Page 36 Using TEST mode allows each protection point to be checked for proper operation. The touchpad sounds a single beep every 40 seconds as a reminder that the system is in the Test mode. Alarm messages are not sent to your Customer Care Center while Test mode is on. 1 Disarm the system and close all protected windows, doors, etc.
  • Page 37: Trouble Conditions

    "Check" and he word CHECK on the touchpad's display, accompanied by a "Battery" Displays "beeping" at the touchpad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK" and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires your attention.
  • Page 38 Words or letters in parentheses ( ) are those that are displayed on English Display touchpads. Other Trouble COMM. FAILURE (or FC) Displays Any “beeping” that accompanies a trouble SYSTEM LO BAT display can be stopped (or BAT with no by depressing any key zone No.) on the touchpad or by...
  • Page 39 Other Trouble AC LOSS Displays (or NO AC) (Continued) Busy-Standby (or dI) OPEN CIRCUIT (or OC) Long Rng Trbl (or bF) TELCO FAULT (or CHECK 94) If there is no touchpad display at all, and the READY indicator Total Power Failure is not lit, operating power (from AC and back-up battery) for the system has stopped and the system is inoperative.
  • Page 40 Taking Care of The components of your security system are designed to be as Your System maintenance-free as possible. However, to make sure that your system is in reliable working condition, do the following: 1. Test your system weekly . 2.
  • Page 41: Fire Alarm System (If Installed)

    THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will sound their alarms and automatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Touchpad(s) and any external sounders.
  • Page 42 THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS Manually 1. Should you become aware of a fire emergency before your smoke or Initiating heat detectors sense the problem, go to your nearest touchpad and manually initiate an alarm by pressing the panic key assigned for a Fire Alarm FIRE emergency for 2 seconds.
  • Page 43 THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's National Fire Alarm Code (NFPA 72) noted below. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke detector installed outside of each separate sleeping area, in the immediate vicinity of the bedrooms and on each additional story of the...
  • Page 44 THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS FLOOR BACK DOOR 1 FLOOR • • BACK • FRONT – 44 – Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1.
  • Page 45 FUNCTION PROCEDURE Check Zones Press READY key. Arm System Enter code. Press arming key desired: (AWAY, STAY, NIGHT-STAY, INSTANT) Quick Arm Press #. Press arming key desired: (if programmed) (AWAY, STAY, INSTANT) Bypass Zone(s) Enter code. Press BYPASS key. Enter zone number(s) to be bypassed (use 2-digit entries).
  • Page 46 SOUND CAUSE LOUD, FIRE ALARM INTERRUPTED * Touchpad & Ext. LOUD, BURGLARY/AUDIBLE CONTINUOUS * EMERGENCY ALARM Touchpad & Ext. ONE SHORT BEEP a. SYSTEM DISARM (not repeated) b. SYSTEM ARMING ATTEMPT Touchpad only WITH AN OPEN ZONE. c. BYPASS VERIFY ONE SHORT BEEP a.
  • Page 47 SOUND CAUSE LOUD, FIRE ALARM. INTERRUPTED* Touchpad & Ext. LOUD, BURGLARY/AUDIBLE CONTINUOUS* EMERGENCY ALARM. Touchpad & Ext. ONE SHORT BEEP a. SYSTEM DISARM. (not repeated) b. SYSTEM ARMING ATTEMPT Touchpad only WITH AN OPEN ZONE. c. BYPASS VERIFY. ONE SHORT BEEP a.
  • Page 48: Industry Canada

    NOTE: This is a “Grade A” Residential System RADIO FREQUENCY EMISSIONS Federal Communications Commission (FCC) Part 15 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 49 Industrie Canada AVIS: l’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d’exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur.
  • Page 50 Features Exit Delay Entry Delay 1 Entry Delay 2 Night-Stay Zones Quick Arm Quick Bypass Automatic Paging Keyswitch Arming (circle type of LED lighting) Up and About Schedule Function Keys Single-Button Arming Step Arming Paging (see Paging chart below) Time/Date Display Macro Key 1 Macro Key 2 Macro Key 3...
  • Page 51: User Setup

    User Setup The following chart will help keep track of system users. Copies should be distributed to the partition 1 and partition 2 masters for their records. To program a user attribute: Enter system/partition master code + [8] + user no. + “#” command listed in column heading… User User User’s Part(s).
  • Page 52: Paging Setup

    User Setup (continued) (Enter system/partition master code + [8] + user no. + “#” command listed in column heading…) User User User’s Part(s). Name (system master only) [#] [3] + part(s) + [#] part. 2 master Authority Levels: 0 = standard user 1 = arm only 2 = guest 3 = duress...
  • Page 53: List Of Output Devices

    Schedules master code + [#] + [6] [4]) Event Device No. (see list below) for “01” events: enter 01-18 Events: 00 = clear event 01 = device on/off 02 = user access List of Output Devices Device Description Group No. Partition Start Time/...
  • Page 54 WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
  • Page 55 Notes...
  • Page 56 Terms and Conditions Applying to Sale of Equipment /LPLWHG :DUUDQW\ Any part of the system, including the wiring, installed under this Agreement which proves to be defective in material or workmanship within 90 days of the date of completion of installation will be repaired or replaced at ADT's option with a new functionally operative part.
  • Page 57 ADT Security Systems, Inc. assumes no responsibility for any errors which may appear in this publication. ADT Security Services, Inc. One Town Center Rd. Boca Raton, FL 33486 K5309V2 1/02 A L L R I G H T S R E S E R V E D Copyright ©...

This manual is also suitable for:

Sasw3000enSecurity manager 3000enSafewatch pro 3000en

Table of Contents