In fields 40, 41, 42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; # +11 for ; # +12 for
#; # +13 for a 2-second pause.
40 PABX ACCESS CODE
Enter 6 digits. If fewer than 6 digits are entered, exit
by pressing
(and press 41, if entering next field).
To clear entries from field, press 40 .
41 PRIMARY PHONE NO.
Enter up to 20 digits; do not fill unused spaces. If
fewer than 20 digits entered, exit by pressing
press 42, if entering next field). To clear entries from
field, press 41 .
42 SECONDARY PHONE NO.
Enter up to 20 digits; Do not fill unused spaces. If
fewer than 20 digits entered, exit by pressing
press 43, if entering next field). To clear entries from
field, press 42 .
43 PRIMARY SUBSCRIBER ACCOUNT NUMBER
44 SECONDARY SUBCRIBER ACCOUNT NUMBER
For fields 43 and 44:
Enter 0–9; # +11 for B; # +12 for C; # +13 for D;
# +14 for E; # +15 for F. Enter
dialer reporting is to be used. If only 3 digits used,
exit by pressing
(and press next field).
To clear entries from field, press 43 or 44 .
Examples:
For Acct. 1234 , enter:
For Acct. B234 , enter:
45 PHONE SYSTEM SELECT
If Cent. Sta. IS NOT on a WATS line: 0 = Pulse Dial;
1 = Tone Dial; if Cent. Sta. IS on a WATS line: 2 = Pulse
Dial ; 3 = Tone Dial.
46 REPORT FORMAT
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
† Entry of a number other than the one specified will give unpredictable results.
DIALER PROGRAMMING ( 40 – 52)
|
|
|
|
|
(and
(and
| | |
[15 15 15 15]
| | |
as 4th digit, if 3+1
1 | 2 | 3 | 4
#+11| 2 | 3 | 4
[1]
[7]
[7]
Primary
Secondary
47 SPLIT/DUAL REPORTING
0 = Disable (Backup report only)
TO PRIMARY PHONE No.
1 = Alarms, Restore, C a n c e l
2 = All except Open/Close, T e s t
3 = Alarms, Restore, C a n c e l
4 = All except Open/Close, Test
5 = A l l
TO PRIMARY PHONE No. TO PAGING No. * (Secondary)
6 = All except O p e n /Close
7 = All r e p o r t s
8 = All r e p o r t s
9 = All e x c e p t Open/Close
*
Will report users 5-16 and, if using wireless button-type
devices, will report the zone number of the arm or disarm
button (10-25). Open/Close for users 1-4 are not reported.
**
See Installation Instructions for an explanation of the paging
format.
48 DIALER DLY (BURG/FIRE) (in sec)
0 = no; 1 = 15; 2 = 30; 3 = 45; 4 = 60;
5 = 120. 0 for UL installations.
49 PERIODIC TEST REPORT
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days
(Enter Test Code in field 64.)
50 TEST REPORT OFFSET

 KRXU 
KRXUV 7LPH WR VW UHSRUW IURP SURJUDPPLQJ RU
GRZQORDGLQJ
51 SESCOA/RADIONICS SELECT
0 = Radionics (0 – 9, B – F reporting); 1 = SESCOA
(0 – 9 only reporting). Select 0 for all other formats.
52 CANCEL VERIFY
0 = no; 1 = yes
– 4 –
[0]
TO SECONDARY PHONE No.
Others
Open/Close, Test
A l l
A l l
A l l
Alarms, Open/Close, for users
5-25*, Troubles
Alarms, Troubles
Alarms, Open/Close, for users
5-25*, Troubles
Open/ C l o s e f o r u s e r s
5 - 2 5 *
[10]
Burg/Fire
[0]
[2]
 KRXUV 
 KRXUV 
[0]
[1]
|


Advertisement