CERTIFICATION AND CODE REQUIREMENTS

This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation
must conform with local codes, or in absence of local codes, the following standards as applicable.
In the U.S. the installation must conform with:
National Fuel Gas Code, ANSI Z223.1/NFPA 54
(latest edition).
Recreational Vehicles Code, ANSI A119.2 (latest edition).
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280.
If an external electrical source is utilized, the refrigerator, when
installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, the National Elec-
trical Code, ANSI/NFPA 70 - (latest edition).
VENTILATION REQUIREMENTS
Ventilation is one of the requirements for proper cooling
unit operation. The installation should be made in such a man-
ner as to separate the combustion system from the living space
of the mobile home or recreational vehicle. Openings for air
supply or for venting of combustion products should have a
minimum dimension of not less than 1/4 inch.
Proper installation requires one lower fresh air intake and one
upper exhaust vent. Certified installations require one roof
vent and one
vent and one
lower side vent. The ventilation kits shown in this
vent
manual have been certified for use with RM2620 and
RM2820. The table below displays the components and their
part no.
Certifi ed vent system kits
Kit no.
Components
4A
Roof Base
Roof Cover
Lower Side Vent
* Replace "XXX" with the color code numbers. For color codes,
contact your supplier. For further information, contact your dealer or
distributor.

INSTALLATION INSTRUCTIONS

Part no.
3103633.XXX*
3103634.XXX*
3109350.XXX*
In CANADA, the installation must conform with:
Natural Gas and Propane Installation Code, CSA B149.1
CSA Z240 RV Series, Recreational Vehicles.
Current CSA Z240.4, Gas-equipped Recreational Vehicles
and Mobile Housing.
If an external electrical source is utilized, the refrigerator,
when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, the Canadian
Electrical Code, CSA C22.1, Parts I and II - (latest edition).
The ventilation kits must be installed and used without modi-
fication! An opening toward the outside at floor level in the
refrigerator compartment has be provided for ventilation of
heavier-than-air fuel gases. The lower vent of the recommended
kits is provided with proper size openings. The flow of combus-
tion and ventilating air must not be obstructed.
The lower side vent is fitted with a panel, which provides an ad-
equate access opening for ready serviceability of the burner and
control manifold of the refrigerator. This should be centered on
the back of the refrigerator.
NOTE! While washing the RV - do not spray any water
through the refrigerator vents.