Attribute
Main item
LENS
Lens drive
C.B./Zoom
Adj.History
DMC-LS1PP / DMC-LS1PL / DMC-LS1EB / DMC-LS1EG / DMC-LS1EGM / DMC-LS1GC / DMC-LS1GK / DMC-LS1GN / DMC-LS1GT / DMC-LS1SG
Sub item
Error code
High 4 bits Low 4 bits
OIS
1800
1000
2000
3000
4000
5000
6000
7000
0100
0200
0300
0400
Zoom
0010
0020
0030
0040
Focus
0001
0002
Lens
1801
0000
1802
0000
OIS
1900
2000
3000
4000
5000
6000
7000
8000
9000
A000
B000
C000
D000
E000
Contents (Upper)
Check point (Lower)
PSD (X) error. Hall element (X axis) position detect error in OIS unit.
OIS Unit
PSD (Y) error. Hall element (Y axis) position detect error in OIS unit.
OIS Unit
GYRO (X) error. Gyro (IC7102: X axis) detect error on Main C.B.A..
IC7102 (Gyro element) or IC6001 (VENUS PLUS)
GYRO (Y) error. Gyro (IC7101: Y axis) detect error on Main C.B.A..
IC7101 (Gyro element) or IC6001 (VENUS PLUS)
MREF error (Reference voltage error).
IC7002 (LENS drive) or IC6001 (VENUS PLUS)
Drive voltage (X) error.
VENUS PLUS AD value error, LENS Unit, LENS flex breaks etc.
Drive voltage (Y) error.
VENUS PLUS AD value error, LENS Unit, LENS flex breaks etc.
HP Low detect error (C.B. encoder (full retract) always Low detect).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
HP High detect error (C.B. encoder (full retract) always High detect).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
ENC1 detect error (C.B. motor encoder detect error).
FP9001-(3) signal line or IC6001 (VENUS PLUS)
ENC2 detect error (C.B. motor encoder detect error).
FP9001-(5) signal line or IC6001 (VENUS PLUS)
HP Low detect error (Zoom encoder always Low detect error).
FP9001-(3, 5) signal line or IC6001 (VENUS PLUS)
HP High detect error (Zoom encoder always High detect error).
FP9001-(3, 5) signal line or IC6001 (VENUS PLUS)
ENC1 detect error (Zoom encoder detect error).
FP9001-(3) signal line or IC6001 (VENUS PLUS)
ENC2 detect error (Zoom encoder detect error).
FP9001-(5) signal line or IC6001 (VENUS PLUS)
HP Low detect error (Focus encoder always Low detect error).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
HP High detect error (Focus encoder always High detect error).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
Power ON time out error.
Lens drive system
Power OFF time out error.
Lens drive system
OIS adj. Yaw direction amplitude error (small)
OIS adj. Pit direction amplitude error (small)
OIS adj. Yaw direction amplitude error (large)
OIS adj. Pit direction amplitude error (large)
OIS adj. MREF error
OIS adj. time out error
OIS adj. Yaw direction off set error
OIS adj. Pit direction off set error
OIS adj. Yaw direction gain error
OIS adj. Pit direction gain error
OIS adj. Yaw direction position sensor error
OIS adj. Pit direction position sensor error
OIS adj. other error