I.listings And Code Approvals; Description Of The R-Cast Wall Furnace - Royal R-CAST Owner's Manual And Installation Instructions

Table of Contents

Advertisement

R-CAST SERIES WALL FURNACE
I. LISTINGS AND CODE APPROVALS.
U.S. Certification.
The R-Cast Series Room Heater has been tested in
accordance with the ANSI standard Z21.88 1998 and
UL307B and has been listed by UL for installation and
operation as described in these Installation and
Operating Instructions. All components are A.G.A. or
UL safety certified.
Canada Certification.
The R-Cast Series Room Heater has been tested in
accordance with CSA 2.33-M98 and has been listed by
UL for installation and operation as described in these
Installation and Operating Instructions. All components
are C.G.A. or C.S.A. safety certified.
Local Codes.
Check with your local building code agency prior to
installing this heater to ensure compliance with local
codes, including the need for permits and follow-up
inspections. This installation must conform with local
codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1-latest edition, in
the U.S.A. and the CANI-B149-latest edition, in Canada.
A manufactured home (mobile home) installation must
conform with the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, or, when
such a standard is not applicable, the Standard for
Manufacturer Home Installations, ANSI A225.1.
II. DESCRIPTION OF THE HEATER SYSTEM.
The R-CAST is a direct vent wall furnace. Combustion air is supplied from outside, not from inside the house as with
other types of heaters.
The installation of this R-CAST system consists of
the following:
1. Appliance
2. Venting System
3. Termination
Optional components include:
1. Fan Kit
12-99
This heater is approved for installation in bed-
rooms and mobile homes in the United States
and Canada.
Efficiency.
The efficiency rating of the appliance is a product
thermal efficiency rating determined under continu-
ous operating conditions and was determined inde-
pendently of any installed system.
If any assistance is required during installation please
contact your local dealer.
ote: Illustrations throughout these
N
instructions reflect typical installations and
are for design purposes only. Actual instal-
lation may vary slightly due to individual
design preferences. However, minimum
and maximum clearances must be main-
tained at all times.
The illustrations and diagrams used
throughout these installation instructions
are not drawn to scale.
Note: Operation of a direct vent heater may
be sporadic in high wind situations.
3
30750B

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-cast-aR-cast-g

Table of Contents