Royal R-CAST Owner's Manual And Installation Instructions

Advertisement

Quick Links

WARNING!
If the information in this manual is not fol-
lowed exactly, a fire or explosion may result
causing property damage, personal injury or
loss of life.
-Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire
department.
-Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING!
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information, consult
a qualified installer, service agency or the
gas supplier.
Hearth Technologies Inc.
20802 Kensington Blvd.
Lakeville, MN 55044
R-CAST
CENTENNIAL
OWNER'S MANUAL
AND INSTALLATION INSTRUCTIONS
FOR YOUR SAFETY:
The appliance area must be kept clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
This wall furnace may be installed with a vertical
or horizontal direct vent termination system.
This manual must be used for installation of the
R-CAST, R-CAST-A, and R-CAST-G Gas-Fired
Wall Furnace and retained by the homeowner for
operating and maintenance instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Royal R-CAST

  • Page 1 WARNING! This manual must be used for installation of the Improper installation, adjustment, alteration, R-CAST, R-CAST-A, and R-CAST-G Gas-Fired service or maintenance can cause injury or Wall Furnace and retained by the homeowner for property damage. Refer to this manual. For operating and maintenance instructions.
  • Page 2: Table Of Contents

    R-CAST SERIES WALL FURNACE PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE. Table of Contents I.Listings and Code Approvals........................3 Description of the R-CAST Wall Furnace..................3 III. Heater System Components ......................4 Pre-Installation Preparation......................8 A. Gas Pressure........................... 8 B. High Altitude Installation ......................8 C.
  • Page 3: I.listings And Code Approvals

    Manufacturer Home Installations, ANSI A225.1. II. DESCRIPTION OF THE HEATER SYSTEM. The R-CAST is a direct vent wall furnace. Combustion air is supplied from outside, not from inside the house as with other types of heaters. ote: Illustrations throughout these...
  • Page 4: Heater System Components

    R-CAST SERIES WALL FURNACE III. APPLIANCE SYSTEM COMPONENTS. The table below is a list of only those components which may be safely used with this appliance. Catalog # Description: R-CAST Direct Vent Wall Furnace - Black - Natural Gas, Standing Pilot.
  • Page 5 R-CAST SERIES WALL FURNACE SLD Series Venting System Components Catalog # Description: SL-SCD Storm Collar SL-FWD Wall Firestop (1 pair) SL-FCD Ceiling Firestop SL-WBD Wall Strap Snorkel Termination (14'') Horizontal Kit (Horizontal Termination Cap, One 90° Black Elbow, Wall Thimble, 24”...
  • Page 6 R-CAST SERIES WALL FURNACE TYPICAL ASSEMBLY 7-99 30750A...
  • Page 7 R-CAST SERIES WALL FURNACE Horizontal Termination Cathedral Ceiling Retro-Fit Installation COMMON INSTALLATIONS Vertical Flat Ceiling 7-99 30750A...
  • Page 8: Pre-Installation Preparation

    R-CAST SERIES WALL FURNACE IV. PRE-INSTALLATION PREPARATION. WARNING! THIS APPLIANCE MAY ONLY USE THE APPROVED VENTING SYSTEMS SHOWN IN THIS INSTALLATION. IT MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVICING A SEPA- RATE SOLID FUEL OR GAS FUEL BURNING APPLIANCE.
  • Page 9: Step-By-Step Installation Of The System

    R-CAST SERIES WALL FURNACE V. STEP-BY-STEP INSTALLATION OF THE R-CAST SYSTEM. INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE HEATER SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
  • Page 10 R-CAST SERIES WALL FURNACE VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 2’ MIN. (.6 m) 4’ MAX. (1.2 m) 3’ MIN. (.9 m) 6’ MAX. (1.8 m) 4’ MIN. (1.2 m) 8’ MAX. (2.4 m) thru 18’ MAX. (5.4 m) 8’...
  • Page 11 R-CAST SERIES WALL FURNACE 1. Preparing the Wall for Horizontal Termination. The SLD-Series Direct Vent Pipe is unitized and When using the SLD-Series system, a hole measur- twist-locks together. For the twist-lock procedure, ing 10” wide and 10” high must be cut and framed in consult Figure 5 and do the following: the exterior wall where venting will be terminated.
  • Page 12: Vertical Termination

    R-CAST SERIES WALL FURNACE Note: For buildings with vinyl siding, a Vinyl Siding Standoff should be installed between the vent cap and the exterior wall. Attach the Vinyl Siding Standoff to the Horizontal Vent Termination. The Vinyl Siding Standoff prevents excessive heat from possible melting the vinyl siding material.
  • Page 13 R-CAST SERIES WALL FURNACE (Vertical Termination Continued.) 3. To bypass any overhead obstructions, the vent system may be offset using a 45° elbow or a 90° elbow. Vent stabilizers have straps for securing these parts to joists or rafters. Plumbers tape may be purchased locally and used in conjunction with vent stabilizers.
  • Page 14: Existing Masonry Chimney Installation

    R-CAST SERIES WALL FURNACE 4. Installing Roof Flashing or Site-produced WARNING! Chase Top. Position roof flashing (or construct a chase and chase top) and secure in place with nails. WHEN VENT SECTIONS EXCEEDING 3 Continue to add vent sections through the roof open-...
  • Page 15: Retrofit Class A Metal Chimney Installation

    D. Existing Class A Metal Chimney Requirements Continued.) Termination. Measure and record the chimney dimensions to In many cases where an R-CAST is replacing a determine total flexible liner requirements. woodstove, much of the existing Class A Metal Follow the liner manufacturer’s instructions for Chimney can be incorporated into the direct vent sys- installing the liner in the chimney.
  • Page 16 R-CAST SERIES WALL FURNACE Note: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas...
  • Page 17 R-CAST SERIES WALL FURNACE Figure 16 Wiring Diagram Figure 17 HBK95 Fan Wiring Diagram 12-99 30750B...
  • Page 18 R-CAST SERIES WALL FURNACE C. Positioning the Logs 1. Place the Back Log on the Back Log Support and position the log all the way to the back of the support. See Figure 20. Figure 18 - Front Face Removal Figure 20 - Positioning the Back Log B.
  • Page 19 Step 10 - Adjustable Flue Restrictor Snug the screws at the bottom being sure not to over The R-Cast has an adjustable flue restrictor for maxi- tighten. mum performance for vertical installations. The unit is shipped with the restrictor in the open position and Step 12 - Replacing the Front Face.
  • Page 20: Operating Instructions

    R-CAST SERIES WALL FURNACE VI. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING! If you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This gas appliance has a manual ignition device that lights the pilot.
  • Page 21 R-CAST SERIES WALL FURNACE Allow the unit to operate about 15-20 minutes. This will Upon completing the gas line connection, a small give the flame time to reach its height and color before amount of air will be in the lines. When first lighting the making adjustments to the air shutter.
  • Page 22: Maintenance Instructions

    R-CAST SERIES WALL FURNACE VII. MAINTENANCE INSTRUCTIONS Cleaning the Burner and Control Compartment. WARNING! Keep the burner compartment clean. Brush this area with a Do not use this heater if any part has been under clean, dry paint brush and vacuum at least once a year.
  • Page 23: Trouble Shooting

    R-CAST SERIES WALL FURNACE VIII. TROUBLE SHOOTING STANDING PILOT Problem Cause Corrective Action 1. Spark ignitor will not A. Defective ignitor. Replace ignitor. light pilot after B. Misaligned electrode. Spark should be approximately 1/8” to bottom of pilot hood. Adjust gap to give repeated pressing of proper spark.
  • Page 24: Replacement Parts

    R-CAST SERIES WALL FURNACE THIS PAGE LEFT BLANK INTENTIONALLY 12-99 30750B...
  • Page 25: Warranty

    A. BASIC ONE-YEAR WARRANTY. HEARTH TECHNOLOGIES INC., located at 20802 Kensington Boulevard, Lakeville, MN 55044, (“HEARTH”) warrants to the original owner that your new ROYAL Gas Fireplace (the “Product”) will be free from defects in materials and workmanship for a period of one year from the date of installation. During the first year, HEARTH will replace or repair, at its discretion, any defective components (not limited to steel and cast iron components) at its sole cost and expense, including payment of all reasonable labor costs incurred in replacing or repairing such components.
  • Page 26 Attention INSTALLER Please return these Operating & Installation Instructions to the Consumer Hearth Technologies Inc. 20802 Kensington Blvd. Lakeville, MN 55044 2-00 30750 REV C...