Control connectors

WASHER
12V
500mA
MIC
12V
200mA
① LED power indicator
This indicator illuminates when the power is on, and goes out when the power is turned off.
② Power switch
This is the switch for turning on/off the power.
③ AUX terminal
This terminal (HR10A-10R-10S (71) / HIROSE connector) is used to control optional functions. This
can be used as a universal contact circuit.
④ SDI terminal
This is an output terminal (BNC connector) for uncompressed digital video and digital audio signals.
⑤ SYNC terminal
This is an input terminal (BNC connector) for external sync signals.
⑥ DC-IN terminal
This is an input terminal for DC power supply. Make sure to use a power cable that is suitable for the installation conditions
(authorized products, environmental regulations) and conforms to the product's power specifications. Power of two or three times
the rating 90 W may be consumed during power-on, so select a power supply with specifications that prevent a power failure.
⑦ CONT. terminal
This is an input terminal (EPRC05-R12M / TAJIMI connector) for the
pan-tilt head, lens and camera control signals.
receptacle unit
AUX
START
STOP
CONT.
CONT. terminal's pin assignment
Pin No.
Input/output Signal name
RX+
Input
Output
TX+
RX-
Input
Output
TX-
GND
Control connectors
SDI
SYNC
AUX terminal's pin assignment
1
FPU
2
AUX1
3
AUX2
4
AUX3
5
AUX4
6
COM
7
8
9
10
11