Mitsubishi Electric MSZ-WG18VA-H1 Operating And Installing Instructions page 35

Wall-mounted inverter heat pump room air conditioner
Table of Contents

Advertisement

MOVE EYE CONTROL OPERATION...Sensible temperature
The proceed of the unit's temperature control is a gerneral temperature control proceed, that accord to the temperature
of wall, floor and room measured by MOVE EYE sensors (MOVE EYE control operation).
When cancel MOVE EYE control, the gerneral temperature control proceed will instead.
Starting MOVE EYE control
MOVE EYE control operation is activated when MOVE EYE button is pressed with a thin stick in manual COOL mode.
Note:
MOVE EYE control operation is activated when the remote controller is first used following replacement of the
batteries or resetting of the remote controller.
Cancelling MOVE EYE control
MOVE EYE control operation is canceelled when MOVE EYE button is pressed with a thin stick once again.
Note:
If the conditioner is turned OFF without cancelling MOVE EYE control operation, MOVE EYE control operation is
activated the next time the air conditioner is turned ON.
MOVE EYE control operation
The sensors constantly measure the room and floor/wall
temperatures to automatically adjust to the set tempera-
ture by estimating the temperature actually perceived by
a person inside the room ("sensible temperature").
Advantages:
The air inside the room is conditioned quickly to a com-
fortable condition.
The room will not become too cold or hot even when
the air conditioner is kept on for a long period.
MOVE EYE sensor
• When AREA setting is not activated, the sensing range of MOVE EYE Sensor differs depending on the installation
location of the air-conditioner.
Installation
Installation opsition
Image of sensing
range
Driection of sensor
Refer to the description for slide switch setting (Page 4).
•This setting of temperature measurement is mnemonic (previous status setting), this temperature sensor in full range may
detect the radiant temperature of floor / wall in the 150° range (one of three installation spaces, left / center / right); there
fore, the detected temperature may be different, because the standard temperature (near measured value by market-sold
thermometer) is classified according to the temperature near the room or ground and/or wall.
•After maintenance or repair, please install the front frame components properly so as to detect the radiant temperature of
floor / wall.
Installation
Installation
at left
at center
Left
Center
Wall
temperature
Humidity
Floor
temperature
Approx 20%
Approx 50%
Approx 30%
Wall/floor temperature
Room/air temperature
at right
Approx 150 degrees
Right
8
Room
temperature
Sensible
temperature
Advantages of i-see

Advertisement

Table of Contents
loading

Table of Contents