Primary user (radar) on all enabled channels (only when DFS is enabled)
If the device detects competing radar signals on all enabled channels of the WLAN interface,
the F LED is lit and R1/R2 flash. No data traffic is then possible for the next 30 minutes. After this
time, the device runs the scan again and checks whether a primary user still exists. If no primary
user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by restarting the device.
4.6

Reset button

Danger from line voltage
After removing the housing cover, there is a risk of touching live parts in the area of the
connecting terminals of the power supply adapter.
Only authorized personnel is permitted to open the device and carry out any work on the open
device (e.g. connection and disconnection of cables, operating the reset button, replacing the
PLUG)!
Position
The reset button is located below the housing cover on the right-hand side above the cable feed: