Specifications - LG DT22BSSG Owner's Manual

Hide thumbs Also See for DT22BSSG:
Table of Contents

Advertisement

Available languages

Available languages

50
TROUBLESHOOTINg / SPECIFICATIONS
Before Calling for Service (cont.)
Problem
There are no
• The function of this cycle is to
creases left on
remove wrinkles from fabric.
garment after
Steam Fresh™
Odors remain
• Steam Fresh™ did not remove
in clothing after
odor completely.
Steam Fresh™
Flow Sense™
• Ductwork is too long or has too
indicator
many turns/restrictions.
shows four
• Significant blockage of the
bars during the
ductwork due to lint buildup or
drying cycle
debris.
or the display
• The appliance has detected a
shows "d80"
restriction in the external dryer
after drying.
venting.
The display
• The duct work is about 90%-95%
shows
blocked.
"d90", "d95"
("d90" or "d95" error code
displayed 2 hours only)
• house exhaust system blocked.

SPECIFICATIONS

Steam Dryer™ Models
Description
Electrical requirements
Gas requirements
Max. water pressure
Dimensions
Net weight
Drying capacity
- Normal cycle
Possible Causes
DT22BSSG
Steam Dryer
120 V ~ 60 hz 400 W
NG: 4-10.5 inches WC
LP: 8–13 inches WC (Gas Models only)
21.8 ~ 116 psi (150 ~ 800 kPa)
27" (W) X 28 15 / 16 " (D) X 40 3 / 16 " (H), 50 1 / 4 " (D with door open)
68.6 cm (W) X 75 cm (D) X 102 cm (h), 127.5 cm (D with door open)
Gas dryer : 137.6 lbs (62.4 kg)
Electric dryer : 134.5 lbs (61.0 kg)
207 L (22.5 lb/10.2 kg)
• Use an iron to make creases.
• Fabrics containing strong odors should be washed in a
normal cycle.
• Install a shorter or straighter duct run. See the Installation
Instructions.
• Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times may
be longer.
• If exhaust restrictions are sensed by the Flow Sense™
system, the indicator will remain on for two hours after
the end of the cycle. Opening the door or pressing the
POWER button will turn off the display.
• Do not use the dryer until the exhaust system has been
cleaned and/or repaired. Using the dryer with a severely
restricted exhaust is dangerous and could result in a fire
or other property damage.
• Check the outside dryer vent while the dryer is operating
to make sure there is strong airflow.
• If the exhaust system is extremely long, have it repaired or
rerouted.
• Keep the area around the dryer clean and free of clutter.
• Check vent hood for damage or lint clogging.
• Make sure the area around the vent hood is clear.
Solutions