Timer Control Panel; Bridge Control Panel - Furuno BR-2000 Operator's Manual

Bridge alarm monitoring & watch safety system
Table of Contents

Advertisement

3.2 Timer Control panel

In captain's cabin
Enable Light
will lit, whenever the
watch safety system is activated
from captain's cabin
If the pushbutton is pressed, the
audible alarm sound and all lamps
are illuminated in the panel for
test purposes.
Timer Set
switch will activate the
watch safety system
The time period is selected with
intervals of 3, 6, 9 and 12 minutes
Alarm light
will flash in case the
watchkeeper has failed to
acknowledge the watch period
warning in 30 seconds or if any
alarm has not been acknowledged
on the bridge within 60 seconds
Buzzer
will sound in case the
watchkeeper has failed to
acknowledge the watch period
warning in 30 seconds or if any
alarm has not been acknowledged
on the bridge within 60 seconds
The buzzer can only be
acknowledged on the bridge

Hide quick links: