F-1
IDEALARC R3R-400, 500-I, 500 & 600-I WIRING DIAGRAM
PRIMARY CONNECTIONS 4-7, 5-8 AND 6-9
ARE MADE AT THE MAIN TRANSFORMER
TO SUPPLY LINES
TO GROUND
PER
RECONNECT PANEL SHOWN
NATIONAL
CONNECTED FOR LOW VOLTAGE
ELECTRICAL
CODE
H3
X2
3
L3
T2
2
X1
H2
L2
1
H1
L1
ICR
TO PRIMARY
231
232
233
380/500 OR 460/575
PRIMARY CONNECTIONS 1-7, 2-8 AND 3-9
ARE MADE AT THE MAIN TRANSFORMER
TO SUPPLY LINES
TO GROUND
PER
RECONNECT PANEL SHOWN
NATIONAL
CONNECTED FOR 230V
ELECTRICAL
CODE
H3
9
5
X2
3
L3
8
4
T2
X1
H2
L2
2
7
6
H1
L1
1
ICR
TO PRIMARY
231
232
233
230/400V
ELECTRICAL SYMBOLS PER E1537
LEGEND
D5
D6
POCKET AMPTROL SENSING BRIDGE
D7
L1
DC OUTPUT FILTER
R1
10K OHM POT., OUTPUT CONTROL
R2
10K OHM POT., ARC FORCE CONTROL
R3
40 OHM
R4
.4 OHM POCKET AMPTROL SENSING RESISTOR
SW1
POWER SWITCH
SW2
MACHINE/REMOTE SWITCH
SW3
DIAL SELECTOR SWITCH
SW4
OPTIONAL POLARITY SWITCH
(60 Hz ONLY)
SCR1-D1
SCR2-D2
SCR AND DIODE
SCR3-D3
RECTIFIER BRIDGE
D4
T1
MAIN TRANSFORMER
T2
CONTROL TRANSFORMER
T3
POCKET AMPTROL OPTION
TRANSFORMER
ICR
INPUT STARTER
COLORS
A = AMBER
G = GREEN
W = WHITE
Y = YELLOW
( DASHED ITEMS ON WIRING
DIAGRAM ARE OPTIONAL )
2
1
4
1
5
2
6
3
3
1
4
2
CAVITY NUMBERING SEQUENCE
(COMPONENT SIDE OF BOARD)
CONNECTOR AND THESE THREE
LEADS ARE NOT USED WHEN
OPTIONAL POCKET AMPTROL
IS PROVIDED.
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The
specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
All manuals and user guides at all-guides.com

WIRING DIAGRAMS

TO SUPPLY LINES
TO GROUND
PER
NATIONAL
RECONNECT PANEL SHOWN
ELECTRICAL
CONNECTED FOR LOW VOLTAGE
CODE
H3
L3
3
X2
L2
2
T2
18
X1
H2
L1
1
17
H1
16
ICR
231
232
233
COILS
SINGLE, BELOW 346V OR
DUAL VOLTAGE
BONDED GROUNDING LEADS
(R3R-600-I ABOVE CODE 11200 ONLY)
LIFT BALE
INPUT BOX
AND FRAME
11
10
12
COILS
16, 17, & 18 ARE PRESENT
ON 380/500 OR 460/575
MACHINES ONLY.
L1
OPTIONAL POCKET
AMPTROL P.C.
BOARD
1
G
2
Y
J7
3
G
4
1
218
2
219
3
75
J6
4
76
5
77
6
217
5
1
217
6
2
3
75
7
8
4
77
76
75
(SWITCH SHOWN IN LOCAL POSITION)
A
B
C
D
REMOTE CONTROL RECEPTACLE
-
IDEALARC® R3R 375-I, 500-I AND 600-I
PRIMARY CONNECTIONS
TO SUPPLY LINES
TO GROUND
PER
NATIONAL
ELECTRICAL
CODE
H3
9
6
X2
3
L3
8
5
T2
X1
H2
2
L2
7
4
1
H1
L1
ICR
231
232
233
TO PRIMARY
COILS
SINGLE, 346V AND ABOVE
(EXCEPT 380V.)
REMOTE
RECEPTACLE
CONTROL
BASE
CONTROL
BOX
PANEL
233
FAN MOTOR
115 V
201
202
AUXILIARY COILS
66V
66V
(ON BOTTOM PRI.
8
9
7
COIL ASSEMBLIES)
S
S
TOP PRIMARY
10
11
12
16
17
18
1
2
3
BOTTOM PRIMARY
4
5
6
T1
X1
X2
SEC
SEC
D2
D3
D1
D4
RECTIFIER
SCR2
SCR1
BRIDGE
222
223
221
G1 G2 G3
226
220
204
224
225
G
G1 G2 G3 204
203A
Y
115V
201A
2
1 3
G
1 2 3 4 5 6 7 8
J4
T3
J5
SNUBBER BOARD
226
CONTROL
OPTIONAL METER KIT
P.C.
AM
BOARD
VM
-
+
-
+
205
217
206
212 76
214
204
210
210
211
75
76
77
211
77
R1
213
SW3
SW2
TO CONTROL BOX
GROUNDING STUD
E
F
SW4
RECONNECT PANEL SHOWN
TO SUPPLY LINES
4-7, 5-8 AND 6-9
TO GROUND
ARE MADE AT THE
PER
NATIONAL
MAIN TRANSFORMER
ELECTRICAL
CODE
H4
X2
3
L3
H3
T2
L2
2
H2
X1
1
L1
H1
TO PRIMARY
231
ICR
COILS
220/380/415-440
AND
220-230/380-
400/440-460
HIGH TEMP LIGHT
232
A
235
SECONDARY
CHOKE
THERMOSTAT
THERMOSTAT
231
234
235
A
203
66V
S
204
THERE IS NO 10-11-12
CONNECTION ON 380,
220/380/415-440 OR
230/400V MACHINES.
219
X3
218
204
SEC
R4
220
204
D5
R3
SHUNT
SCR3
D6
-
D7
205
204
204
THESE LEADS ARE
PRESENT ONLY WITH
206
204
OPTIONAL METER
KIT.
6
201A
3
201
4
2
1
2
202
J2
1
203
J3
5
203A
204
4
232
1
204
235
2
209
W
3
208
PILOT LIGHT
4
214
235
5
75
J1
6
212
7
213
231
8
217
235
SW1
208
209
204
204
224
R2
L9376
F-1
CONNECTED FOR 220V
RECONNECT PANEL
11
6
9
8
5
10
7
12
4
TO PRIMARY COILS
233
TO PRIMARY
COILS
219
+