Download Print this page

Advertisement

Quick Links

CLEI: M3C3RG0A_ _
Product P/N: 1186002F1
D
ESCRIPTION
The MX2820 M13 MUX is a plug-in unit for
the MX2820 chassis that provides an M13
M13 MUX
multiplexer function to the MX2820 system.
1186002
Two MX2820 M13 MUX modules are used
together to provide a redundant M13 multi-
plexer circuit. The MX2820 M13 MUX:
ACT
Provides 1-to-1 redundancy
ALM
Meets the requirements for NEBS Level 3.
STAT
DS3
TEST
S
AFETY AND
STAT
C
OMPLIANCE
DS1
TEST
Refer to the Safety and Regulatory 
Compliance Notice for this product (P/N 
61186002F1‐17) for detailed safety and 
regulatory information.
Consultez l'avis sur la sécurité et la
conformité à la réglementation pour ce
produit (61186002F1‐17) pour obtenir des
renseignements détaillés sur la sécurité et la
réglementation.
Ausführliche Sicherheits- und regula-
torische Informationen sind in der Konformitätserklärung zur
Sicherheit und Einhaltung von Normen zu diesem Produkt
(61186002F1‐17) aufgeführt.
I
NSTALLATION
After unpacking the unit, inspect it for damage. If damage is found,
file a claim with the carrier and then contact ADTRAN Customer
Service. Refer to the warranty statement on this Job Aid.
This module occupies a MUX slot in the MX2820 chassis. To install
the M13 MUX in the chassis, perform the following steps:
1. Pull the ejector tab into the down position and gently but firmly
push the MUX into the selected MUX slot. Simultaneous thumb
pressure at the top and at the bottom of the MUX ensures a
good seat of the MUX into the backplane connector.
2. Push the ejector tab up and closed against the front panel.
Upon installation, the MUX begins a self-test. This is followed with
the LEDs reflecting the true state of the hardware.
O
S
PERATIONAL
PECIFICATIONS
Operates from A or B input voltage power feeds.
o
–48 VDC Systems: –42 VDC to –56 VDC
o
–24 VDC Systems: –22 VDC to –27 VDC
o
+24 VDC Systems: +22 VDC to +27 VDC
Operates over extended temperature range of –40ºC to +50ºC
(without fans) or –40ºC to +65ºC (with fans)
Storage –40ºC to +85ºC (Relative humidity to 95 percent,
noncondensing)
MX2820
M13 MUX
LED S
Label
ACT
R
ALM
EGULATORY
DS3 STAT
DS3 TEST
DS1 STAT
DS1 TEST
LED S
Label
ACT
ALM
DS3 STAT
DS3 TEST
DS1 STAT
DS1 TEST
Issue Date: November 2011
Document P/N: 61186002F1-22A
A
TATUS FOR
CTIVE
Status
Description
Green
Normal (All OK)
Green/Yellow
Normal and console open
/
(Alternating)
Yellow
Software update in progress
/
Yellow/Red
Self-test failed and console open
(Alternating)
Red
Self-test failed
2
Red (Flashing)
Module has failed
Green
No critical, major, or minor alarms
Red
Major or minor alarm in progress
4
Red (Flashing)
Critical alarm in progress
Green
Normal (DS3 OK)
/
Green/Red
DS3 XCV threshold exceeded
(Alternating)
Red
AIS, OOF, RAI, Idle alarms
2
Red (Flashing)
DS3 LOS or DS3 Failure (critical)
2
Red (Flashing
Single/Burst DS3 code violations
once per event)
Off
No DS3 tests in progress
Yellow
In test (locally originated)
2
Yellow (Flashing)
In test (remotely originated)
Off
All DS1s are disabled
Green
Enabled DS1s normal (All OK)
Green/Red
DS1 XCV threshold exceeded
/
(Alternating)
Red
Non-critical DS1 alarm (CAIS,
LAIS)
4
Red (Flashing)
LOS on an enabled line (critical
DS1 alarm; non-critical system
alarm)
2
Red (Flashing
Single/Burst RX DS1 code viola-
once per event)
tion
Off
No DS1 tests in progress
Yellow
In test (locally originated)
2
Yellow (Flashing)
In test (remotely originated)
S
TATUS FOR
TANDBY
Status
Description
2
Green (Flashing)
Normal (All OK)
Yellow
Software update in progress
Red
Failure
Off
Permanent state during standby
Off
Normal (DS3 OK)
2
Red (Flashing)
In test (remotely originated)
Off
Permanent state during standby
Off
Normal (DS1s OK)
2
Red (Flashing)
DS1 Failure
Off
Permanent state during standby