Agilent Technologies 10400B Series User Manual

Agilent Technologies 10400B Series User Manual

Miniature passive oscilloscope probes

Advertisement

Quick Links

User's Guide
Publication number 10433-92002
October 2006
For Safety information, Warranties, Regulatory information, and publishing information,
see the pages at the back of this book.
©
Copyright Agilent Technologies Company 1998-1999, 2006
All Rights Reserved.
Agilent 10400B Series Miniature
Passive Oscilloscope Probes
A

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 10400B Series

  • Page 1 Publication number 10433-92002 October 2006 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. © Copyright Agilent Technologies Company 1998-1999, 2006 All Rights Reserved. Agilent 10400B Series Miniature Passive Oscilloscope Probes...
  • Page 2: Table Of Contents

    Office. • If the shipping container is damaged, or the cushioning materials show signs of stress, notify the carrier as well as your Agilent Technologies Sales Office. Keep the shipping materials for the carrier’s inspection. The Agilent Technologies office will arrange for repair or replacement at Agilent...
  • Page 3 The Agilent 10400B Series Miniature Passive Oscilloscope Probes provide improved usability and performance of the Agilent 10400A Series Probes, and they offer a broader range of accessories. The Agilent 10400B Series Probes replace the Agilent 10400A Series, but maintain compatibility with them. To select the appropriate replacement probe, see the following table.
  • Page 4: Probe Parts Supplied

    Agilent 10400B Series Miniature Passive Oscilloscope Probes Probe parts supplied Probe parts supplied Parts supplied with the Agilent 10400B Series Probes are shown below. label.cdr Parts of the Agilent 10400B Series Probes Agilent 10400B Series Probe Parts Item Description Quantity...
  • Page 5 Agilent 10400B Series Miniature Passive Oscilloscope Probes Probe parts supplied Replacement and Optional Parts Item Replacement Part Agilent Part Number 10400B Series Probe Models: 10433B, 10436B, (For replacement, order the entire probe assembly.) 10437B, 10439B, 10440B, 10441B, or 10442B. 10433B probe tip (qty. 5) — Blue 5063-2167 10436B probe tip (qty.
  • Page 6 Agilent 10400B Series Miniature Passive Oscilloscope Probes Probe parts supplied Available accessories • Agilent 10467-68701 SMD microclips (2 yellow and 2 green) for connection to SMT parts with lead spacings of 0.5 mm (0.020 inch) to 0.8 mm (0.032 inch).
  • Page 7 Agilent 10400B Series Miniature Passive Oscilloscope Probes Probe parts supplied • Agilent N2766A (qty. 25) horizontal mini-probe socket.
  • Page 8: Probe Characteristics

    Agilent 10400B Series Miniature Passive Oscilloscope Probes Probe characteristics Probe characteristics Agilent 10400B Series Probes Operating Characteristics Approximate Lengths of Probe Propagation Delay Approximate probe length = 1 meter 4.5 ns Approximate probe length = 1.5 meters 6.7 ns Approximate probe length = 2 meters...
  • Page 9 Weight 2.6 oz. Indoor Use This symbol indicates that the Agilent 10400B Series Probes are in compliance with European product regulations, including the EMC Directive and the Low Voltage Directive. This symbol indicates that the Agilent 10400B Series Probes are in compliance with Australian product regulations.
  • Page 10: Bandwidth Considerations

    Agilent 10400B Series Miniature Passive Oscilloscope Probes Bandwidth considerations Bandwidth considerations The dominant probe limitation to system bandwidth is its input capacitance, assuming that the high-frequency compensation adjustments have been made. The displayed bandwidth of any measurement system using an oscilloscope and probe is determined by four factors: probe input capacitance, source impedance, source bandwidth, and oscilloscope bandwidth.
  • Page 11 Agilent 10400B Series Miniature Passive Oscilloscope Probes Bandwidth considerations Infiniium Oscilloscope Compatible 10400B Series Probe 54830A Series 10433B, 10439B, 10440B MSO/DSO601xA 10433B, 10437B, 10439B, 10440B, 10442B MSO/DSO603xA 10433B, 10437B, 10439B, 10440B, 10442B MSO/DSO605xA 10433B, 10437B, 10439B, 10440B, 10442B MSO/DSO610xA 10433B, 10437B, 10439B, 10440B, 10442B...
  • Page 12: Safety Considerations

    Cleaning the probe If the Agilent 10400B Series Probe requires cleaning, disconnect it from all power sources and clean it with a soft cloth dampened with a mild soap and water solution. Make sure the probe is completely dry before reconnecting it to a power source.
  • Page 13 Agilent 10400B Series Miniature Passive Oscilloscope Probes To operate the probe C A U T I O N Do not solder probe tip to any surface. Solder will damage the probe tip. C A U T I O N If you are using the probe without any accessories, the probe could cause a short if you drop it within the circuit.
  • Page 14 Agilent 10400B Series Miniature Passive Oscilloscope Probes To operate the probe The retractable hook tip. Attach the hook tip to a probing point by pressing the retractable hook tip body towards the probe body. Place the hook tip around the probing point, then release the retractable hook tip body.
  • Page 15: Compensation Adjustments

    Low-frequency compensation is adjusted when the probe is first connected to the oscilloscope. Probe compensation will usually hold over all the attenuator ranges when used with a Agilent Technologies oscilloscope. If the input capacitance of the oscilloscope changes as ranges are switched, compensation must be adjusted each time a new range is selected.
  • Page 16 Agilent 10400B Series Miniature Passive Oscilloscope Probes Compensation adjustments Adjusting high-frequency compensation Do Low-Frequency Compensation First You must do the low-frequency compensation procedure described previously before doing this high-frequency compensation procedure. To compensate for cable loss in your probe, you’ll need the equipment listed below.
  • Page 17 © Copyright Product Warranty Limitation of Warranty Certification Agilent Technologies This Agilent Technologies The foregoing warranty Agilent Technologies Company 1998-1999, 2006. product has a warranty shall not apply to defects Company certifies that this All Rights Reserved. against defects in material...
  • Page 18 Safety About this edition W A R N I N G This apparatus has been This is the Agilent 10400B designed and tested in Series Miniature Passive The Warning sign denotes a accordance with IEC Oscilloscope Probes User’s hazard. It calls attention to Publication 1010, Safety Guide.
  • Page 20 Agilent Technologies Printed in the USA Manual Part Number 10433-92002 *10433-92002*...