● Setting
- Set the width of Timer0Active pulse
Set the following value to "TimerDuration" register. Setting value is Float type.
- Set the delay of Timer0Active pulse
Set the following value to "TimerDelay" register. Setting value is Float type.
- Select the source of Timer0Active pulse to start
Select the following value to "TimerTriggerSource" register. Setting value is Enumeration type.
TimerTriggerSource
ExposureStart (*)
● Note
"TimerTriggerSource" operation is as follows,
Line0Active is available in
FrameTrigger is available in both
FrameTriggerError.
ExposureStart is available in both
Timer0Active pulse delays TiggerDelay+TimerDelay[us].
FrameTriggerError.
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
TimerDuration
Minimun (*)
Maximum
TimerDelay
Minimun (*)
Maximum
Off
Disables the timer trigger.
Line0Active
Starts when Line0 is active.
Starts with the reception of the Exposure Start
FrameTrigger
Starts with the reception of the Frame Start Trigger.
HardwareTrigger mode, and to be responsed at FrameTriggerError.
HardwareTrigger and Software Trigger mode, and not to be responsed at
HardwareTrigger and Software Trigger mode, and not to be responsed at
Pulse width
0.00[μs]
2000000.00[μs]
* initial factory setting
Delay value
0.00[μs]
2000000.00[μs]
* initial factory setting
Description
* initial factory setting