Electric Start-Up (20Hp Honda Engine) - MULTIQUIP STREET PRO 2 Operation And Parts Manual

Gasoline-powered concrete/asphalt saw
Table of Contents

Advertisement

MQ SP2 CE SAW — ELECTRIC START-UP (20HP HONDA ENGINE)

ELECTRIC START-UP (20HP HONDA ENGINE)

CAUTI
CAUTI
CAUTION
CAUTI
CAUTI
DO NOT attempt to operate the saw until
this manual has been read and thoroughly
understood. Engine operating steps may
vary. See included engine manufacturer's
operating manual.
WARNING
WARNING
WARNING
WARNING
WARNING
When the engine is running the cutting
blade is ALWAYS rotating . Keep
hands and feet clear of rotating blade.
Raise the saw to full height when
maneuvering the saw within the cutting
area.
All displacement of the machine
outside the cutting area shall be carried
out with the tool not in rotation.
WARNING
WARNING
WARNING
WARNING
WARNING
NEVER place hands or feet inside the belt
guard or blade guard while the engine is
running. ALWAYS shut the engine down
before performing any kind of
maintenance service on the saw.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
Ensure the work area is clear of tool, debris, and
unauthorized people.
CAUTI
CAUTI
CAUTION
CAUTI
CAUTI
The engine governor speed has been set at the factory.
Changing the governor speed could damage the blade and/
or the saw or create a risk for injury to the operator.
CAUTI
CAUTION
CAUTI
CAUTI
CAUTI
Keep Wheel Clamp applied (lever DOWN)until
completely ready for cutting operation.
MQ SP2 CE SAW — OPERATION & PARTS MANUAL — REV. #6 (09/08/06) — PAGE 29
The following start-up procedure makes reference to a HONDA
20 HP Engine (Electric Start)
D
1. Ensure the wheel clamps are in the LOCKED position.
2. Ensure the engine Shutdown switch on the handlebar and
D
Figure 30. Wheel Clamp
(Figure 30).
the engine ON/OFF switch on the engine are both in the
OFF position to avoid accidental starting. (Figures 31 and
32)
The Engine Shutdown Switch located
on the handlebar (Figure 31) serves
both as an Emergency Engine Shut-
NOTE
Off and as the primary Shutdown
switch. This allows the operator to
shutdown the saw safely away from
moving parts.
After shutdown on Electric Start models,
ensure the Engine Start switch
NOTE
(Figure 32) is turned to the OFF
position to avoid battery discharge and
accidental starting.
Figure 31. Engine Shutdown Switch (Handlebar)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp2 ce13h20Sp2 sce13h20Sp2 sce20h20

Table of Contents