R-410A
ZZ SERIES
6 - 12.5 Ton
60 Hertz (Export Only)
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Preceding Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Rigging And Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ZZ07-14 Unit Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Power And Control Wiring. . . . . . . . . . . . . . . . . . . . . . . . . 16
Typical Field Power and Control Wiring . . . . . . . . . . . . . . . . 18
Typical Power Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Blower Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Smart Equipment™ unit control board . . . . . . . . . . . . . . . . . 47
1 ZZ07-14 Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 ZZE07-14 Corner Weights . . . . . . . . . . . . . . . . . . . . . . . . 8
3 ZZE07-14 Unit Accessory Weights . . . . . . . . . . . . . . . . . . 9
4 ZZ07-14 Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . 13
7 Control Wire Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10 Supply Air Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
1 Unit shipping bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Protective condenser covering . . . . . . . . . . . . . . . . . . . . . 5
4 Supply and return air ducts . . . . . . . . . . . . . . . . . . . . . . . 6
7 Unit 4 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Unit 6 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . 8
9 Center of Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10 ZZE07-08 Unit Dimension . . . . . . . . . . . . . . . . . . . . . . . 10
11 ZZ09-12 Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . 11
12 ZZ14 Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TABLE OF CONTENTS

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Compressor Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
IntelliSpeed Supply Fan Control . . . . . . . . . . . . . . . . . . . . 53
Economizer Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Dry Bulb Changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Single Enthalpy Changeover. . . . . . . . . . . . . . . . . . . . . . . 53
Dual Enthalpy Changeover . . . . . . . . . . . . . . . . . . . . . . . . 53
Auto. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Free Cooling Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Power Exhaust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Setpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Start-Up (Cooling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Start-Up Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
LIST OF TABLES
14 Motor Sheave Datum Diameters . . . . . . . . . . . . . . . . . . 45
15 Additional Static Resistance - ZZ08-14 . . . . . . . . . . . . . 46
16 Additional Static Resistance - ZZ07 . . . . . . . . . . . . . . . . 46
19 ZZ07 Charging Table . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
20 ZZ08 Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
21 ZZ09 Charging Table System 1 . . . . . . . . . . . . . . . . . . . 60
22 ZZ09 Charging Table System 2 . . . . . . . . . . . . . . . . . . . 61
23 ZZ12 Charging Table System 1 . . . . . . . . . . . . . . . . . . . 61
24 ZZ12 Charging Table System 2 . . . . . . . . . . . . . . . . . . . 62
25 ZZ14 Charging Table System 1 . . . . . . . . . . . . . . . . . . . 62
26 ZZ14 Charging Table System 2 . . . . . . . . . . . . . . . . . . . 63
LIST OF FIGURES
15 Side Duct Cover Panels . . . . . . . . . . . . . . . . . . . . . . . . . 15
18 Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
20 Belt Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
21 Altitude/Temperature Correction Factors . . . . . . . . . . . . 38
22 Unit control board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
23 SE-ECO1001-1 Economizer Controller . . . . . . . . . . . . . 55
5834853-YIM-B-0320

Advertisement

Table of Contents
loading

Summary of Contents for Johnson Controls ZZ Series

  • Page 1: Table Of Contents

    R-410A ZZ SERIES 6 - 12.5 Ton 60 Hertz (Export Only) TABLE OF CONTENTS General ......... . 2 Operation .
  • Page 2: General

    Refer to this manual. For assistance or additional information consult a Observe all precautions in the literature, labels, and tags qualified installer, service agency or the gas supplier. accompanying the equipment whenever working on air Johnson Controls Ducted Systems...
  • Page 3 This system uses R-410A Refrigerant which operates at • Economizer Accessory - higher pressures than R-22. No other refrigerant may be Vertical Flow Dry Bulb Economizer Field Installed used in this system. Horizontal Flow Dry Bulb Economizer Field Installed Johnson Controls Ducted Systems...
  • Page 4 D = E-Coat Indoor & Outdoor Coils relocated in the field. (See unit installation manaul). Controls A = Smart Equipment™ B = Smart Equipment + BACnet MSTP, Modbus, N2 COM Card J = Verasys Single Zone K = Verasys Change Over Bypass Johnson Controls Ducted Systems...
  • Page 5: Installation

    You can use the shipping bracket to hold the RAT sensor in the return air stream. See Figure 3 for the Bracket screws factory RAT sensor location and Figure 5 for the sensor relocation. Bracket Figure 1: Unit shipping bracket Johnson Controls Ducted Systems...
  • Page 6: Limitations

    Gas-Fired Central Furnace Standard, ANSI Z21.47a. - Latest Edition Local building codes, and Local gas utility requirements In Canada: Canadian Electrical Code, CSA C22.1 Installation Codes, CSA - B149.1. Local plumbing and waste water codes, and Other applicable local codes. Johnson Controls Ducted Systems...
  • Page 7: Location

    All units require particular clearances for proper operation and the base rails are provided for this purpose. service. Installer must make provisions for adequate LENGTH OF FORKS MUST BE A MINIMUM OF 60 INCHES. combustion and ventilation air in accordance with section 5.3 of Johnson Controls Ducted Systems...
  • Page 8: Zz07-14 Unit Weights

    Figure 9: Center of Gravity Table 2: ZZE07-14 Corner Weights Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) Size Model (Tons) Shipping Operating 33.6 24.8 (7.5) (8.5) (10) (12.5) Johnson Controls Ducted Systems...
  • Page 9: Zze07-14 Unit Accessory Weights

    Power Exhaust Vert Flow Large Footprint Power Exhaust Horiz Flow Large Footprint Hail Guard Kit Large Short Factory Installed Hail Guard Kit Large Tall Factory Installed Flue Extension Kit (1FE0416) Curb Rigid 14" Large Footprint Curb Rigid 24" Large Footprint Johnson Controls Ducted Systems...
  • Page 10: Zze07-08 Unit Dimension

    5834853-YIM-B-0320 Figure 10: ZZE07-08 Unit Dimension Johnson Controls Ducted Systems...
  • Page 11: Zz09-12 Unit Dimensions

    5834853-YIM-B-0320 Figure 11: ZZ09-12 Unit Dimensions Johnson Controls Ducted Systems...
  • Page 12: Zz14 Unit Dimensions

    5834853-YIM-B-0320 Figure 12: ZZ14 Unit Dimensions Johnson Controls Ducted Systems...
  • Page 13: Zz07-14 Unit Clearances

    Table 5: Unit Models used with 1RC0456, 1RC0458 Roof 1TB0401 - Thru the base electrical and thru the curb gas Curb 1TB0403 - Thru the base electrical and gas ZZ07 ZZ08 Johnson Controls Ducted Systems...
  • Page 14: 1Rc0457, 1Rc0459 Roof Curb Dimensions

    ZZ09 ZZ12 1TB0401/1TB0402 - Thru the base electrical and thru the curb gas ZZ14 1TB0403/1TB0404 - Thru the base electrical and gas Johnson Controls Ducted Systems...
  • Page 15: Ductwork

    When fastening ductwork to side duct flanges on unit, insert screws through duct flanges only. DO NOT insert screws through casing. Outdoor ductwork must be insulated and water-proofed. Figure 17: Bottom Supply Opening For Side Duct Conversion Johnson Controls Ducted Systems...
  • Page 16: Condensate Drain

    R-410A compressor lubricants are known to cause long term same minimum gauge as the replaced wire. damage to some synthetic roofing materials. Johnson Controls Ducted Systems...
  • Page 17: Unit Models Used With 1Rc0456, 1Rc0458 Roof Curb . 13 6 Unit Models Used With 1Rc0457, 1Rc0459 Roof Curb . 14 7 Control Wire Sizes

    Refer to Table 7 for control wire sizing and maximum length. Table 7: Control Wire Sizes Wire Size Maximum Length 18 AWG 150 Feet 1. From the unit to the thermostat and back to the unit. Johnson Controls Ducted Systems...
  • Page 18: Typical Field Power And Control Wiring

    R, RC, or RH. OCC is an output from the thermostat to indicate the Occupied X is an input to the thermostat to display Error Status condi ons. Figure 19: Typical Smart Equipment™ Control Wiring Johnson Controls Ducted Systems...
  • Page 19: Electrical Data

    11746 16.5 19.8 29.3 27 147 30.5 28 143 460-3-60 12846 27.8 33.4 46.3 43 147 47.5 44 143 13346 39.7 54.1 50 147 55.4 51 143 14246 41.7 50.2 67.3 62 147 68.5 63 143 Johnson Controls Ducted Systems...
  • Page 20 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 21 11746 16.5 19.8 31.9 29 149 33.2 31 145 460-3-60 12846 27.8 33.4 48.9 45 149 50.2 46 145 13346 39.7 56.8 52 149 58.1 53 145 14246 41.7 50.2 69.9 64 149 71.2 65 145 Johnson Controls Ducted Systems...
  • Page 22 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 23 11746 16.5 19.8 30.6 28 156 31.9 29 152 460-3-60 12846 27.8 33.4 47.6 44 156 48.9 45 152 13346 39.7 55.5 51 156 56.8 52 152 14246 41.7 50.2 68.6 63 156 69.9 64 152 Johnson Controls Ducted Systems...
  • Page 24 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 25 11746 16.5 19.8 33.3 31 158 34.6 32 154 460-3-60 12846 27.8 33.4 50.3 46 158 51.6 47 154 13346 39.7 58.2 54 158 59.4 55 154 14246 41.7 50.2 71.3 66 158 72.6 67 154 Johnson Controls Ducted Systems...
  • Page 26 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 27 30 163 11746 16.5 19.8 33.1 30 167 34.4 32 163 460-3-60 12846 27.8 33.4 50.1 46 167 51.4 47 163 13346 39.7 53 167 59.3 55 163 14246 41.7 50.2 71.1 65 167 72.4 67 163 Johnson Controls Ducted Systems...
  • Page 28 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 29 11746 16.5 19.8 35.8 33 169 37.1 34 165 460-3-60 12846 27.8 33.4 52.8 49 169 54.1 50 165 13346 39.7 60.7 56 169 61.9 57 165 14246 41.7 50.2 73.8 68 169 75.1 69 165 Johnson Controls Ducted Systems...
  • Page 30 3. HACR type per NEC. 4. Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field installed electric heat kits may exceed the factory installed disconnect amperage rating. Johnson Controls Ducted Systems...
  • Page 31: Physical Data

    AK51 AK51 Belt Motor Max Bhp, 3 Phase 1725 1725 1725 Frame size 56HZ FILTERS Quantity - Size 4 - (16 x 16 x 2) 1. 2 in. Throwaway, Standard, MERV 4 (Minimum Efficiency Reporting Value). Johnson Controls Ducted Systems...
  • Page 32 Blower Sheave AK51 AK51 AK51 Belt Motor Max Bhp, 3 Phase 1725 1725 1725 Frame size 56HZ FILTERS Quantity-Size 4 - (16 x 16 x 12) 1. 2 in. Throwaway, Standard, MERV 4 (Minimum Efficiency Reporting Value). Johnson Controls Ducted Systems...
  • Page 33 AK74 AK74 Belt Motor Max Bhp, 3 Phase 1725 1725 1725 Frame size 56HZ FILTERS Quantity - Size 4 - (20 x 20 x 2) 1. 2 in. Throwaway, Standard, MERV 4 (Minimum Efficiency Reporting Value). Johnson Controls Ducted Systems...
  • Page 34 BX52 Motor Max Bhp, 3 Phase 5.25 1725 1725 1725 Frame size 56HZ 145TY FILTERS Quantity - Size 4 - (20 x 20 x 2) 1. 2 in. Throwaway, Standard, MERV 4 (Minimum Efficiency Reporting Value). Johnson Controls Ducted Systems...
  • Page 35 BX54 Motor Max Bhp, 3 Phase 5.25 1750 1750 1750 Frame size 184TZ 184TZ FILTERS Quantity - Size 4 - (20 x 20 x 2) 1. 2 in. Throwaway, Standard, MERV 4 (Minimum Efficiency Reporting Value). Johnson Controls Ducted Systems...
  • Page 36: Options/Accessories

    The tension on the belt should be adjusted as shown in Figure 20. Change the phasing of the Field Line Connection at the factory or field supplied disconnect to obtain proper rotation. Johnson Controls Ducted Systems...
  • Page 37: Belt Adjustment

    Air density correction factors are shown 5. After adjustments are completed re-tighten nuts (A, B in Table 11 and Figure 21. and C). Johnson Controls Ducted Systems...
  • Page 38: Altitude/Temperature Correction Factors

    Corrected BHP = 2.0 x 0.832 = 1.66 rpm needed at 5,000 ft. Suppose that the corresponding BHP listed in the table is 2.0. This value must be corrected for elevation. BHP at 5,000 ft. = 2.0 x .832 = 1.66 Johnson Controls Ducted Systems...
  • Page 39: Airflow Performance

    0.21 0.24 12 (10.0), 4400 0.20 0.79 0.27 0.25 0.29 14 (12.5) 4800 0.22 0.91 0.31 0.30 0.34 5200 0.24 1.04 0.35 0.35 0.39 5600 0.26 1.17 0.39 0.41 0.45 6000 0.28 1.30 0.43 0.48 0.52 Johnson Controls Ducted Systems...
  • Page 40: Zz07-14 Side Duct Application (Belt Drive)

    2.40 2.60 2.80 2.98 1014 3.17 1064 3.35 Standard Static Option with Motor rated at 2.4-hp Medium Static Option with Motor rated at 2.4-hp High Static Option with Motor rated at 3.7-hp Exceeds recommended Blower speed Johnson Controls Ducted Systems...
  • Page 41 Standard Static Option with Motor rated at 2.9-hp Medium Static Option with Motor rated at 3.7-hp High Static Option with Motor rated at 5.25-hp Bold Field-supplied BK95 x 1 fixed pulley (p/n 1074787) with Motor rated at 5.25-hp Exceeds recommended Blower speed Johnson Controls Ducted Systems...
  • Page 42: Zz07-14 Bottom Duct Application (Belt Drive)

    4250 2.17 2.34 2.52 2.70 2.88 1000 3.07 1051 3.24 1100 3.42 Standard Static Option with Motor rated at 2.4-hp Medium Static Option with Motor rated at 2.4-hp High Static Option with Motor rated at 3.7-hp Johnson Controls Ducted Systems...
  • Page 43 5800 4.47 1003 4.70 1051 4.92 1099 5.15 6000 4.87 1034 5.10 Standard Static Option with Motor rated at 2.4-hp Medium Static Option with Motor rated at 3.7-hp High Static Option with Motor rated at 5.25-hp Johnson Controls Ducted Systems...
  • Page 44 BK85 BX52 Std. 1750 0.87 1.15 2.8 - 3.8 1VL44 AK79 A50 Med. 1750 0.90 1.15 184TZ 3.4 - 4.4 1VP50 AK79 A52 (12.5) H. Static 5.25 1750 0.90 1.15 184TZ 4.3 - 5.3 1VP56 BK85 BX54 Johnson Controls Ducted Systems...
  • Page 45: Motor Sheave Datum Diameters

    Re-checking set screws Use Table 14 to locate the DD nearest to 4.21 in. Close the and belt tension after 10-12 hrs. run time is sheave to 1 turn open. recommended. New BHP Johnson Controls Ducted Systems...
  • Page 46: Additional Static Resistance - Zz08-14

    3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Ducted Systems...
  • Page 47: Smart Equipment™ Unit Control Board

    24 VAC hot out for smoke detector, condensate overflow and/ accessories for unit shutdown are wired between thermostat or user shutdown relay switching in series connection strip SD-24 and R 24 VAC common for thermostat power Johnson Controls Ducted Systems...
  • Page 48 #1 refrigerant circuit Evaporator Coil temperature Input required for operation; 3.625 VDC reading EC1+ to EC1– with open EC1+ sensor input from 10KΩ @ 77°F, Type III negative circuit. Used in suction line temperature safety. temperature coefficient thermistor Johnson Controls Ducted Systems...
  • Page 49 Output relay circuitry is isolated from other UCB components 24 VAC hot for H1, H2, CN-FAN, AUX HGR, 24V FOR OUTPUTS and the 24 VAC hot source may be from a second FAN C1 and C2 output relay contact switching transformer in the unit Johnson Controls Ducted Systems...
  • Page 50 Three HPS2 trips in a two hour period cause a “High Pressure (left pin) Pressure Switch Switch 1 Lockout” and C2 output is then prevented until alarm reset. Connects through circuit trace to the right LPS2 pin. Johnson Controls Ducted Systems...
  • Page 51 On-board, 2-line x 8-character back-lit display economizer, 4-stage and FDD board parameters ENTER Button for display menu acknowledgment and navigation Button for display menu navigation and zeroing of active CANCEL compressor ASCD timer 4-way Joystick for display menu navigation Johnson Controls Ducted Systems...
  • Page 52 2. We recommend 26 AWG solid, 6-wire (3 twisted pairs) cable as the best fit for fabricating modular cables with the modular jack housing assembly. Be sure the cable you use fits the modular jack housing. The preassembled cables that are available from Anixter (Part No. CBL-NETWORKxxx) use 24 gauge wire. Johnson Controls Ducted Systems...
  • Page 53: Operation

    Stage of Cool % Command" • With a demand for Two Cooling Stages, VFD will operate • Return and outside air dry bulb = dry bulb changeover at the frequency relating to setpoint "Occupied, One Stage of Cool % Command" Johnson Controls Ducted Systems...
  • Page 54: Free Cooling Operation

    De-energizes exhaust fan when economizer output is between zone (or return) temperature and the current cooling below the Economizer Damper Position for Exhaust Fan setpoint is great enough to demand more than one stage of cooling. Johnson Controls Ducted Systems...
  • Page 55: Cable For Fc Buses And Sa Buses In Order Of Preference . 52 18 Smart Equipment™ Economizer Board Details

    Negative of the SA BUS communication Common for SA BUS power and circuit to the UCB. Through the unit wiring harness, may continue communication circuits on to the 4-stage board and/or fault detection & diagnostics board Johnson Controls Ducted Systems...
  • Page 56 24V~ IN Pin connections at right on upper edge of economizer board 24 VAC common connection to power the economizer board. 24 VAC transformer Common referenced to Connects through circuit traces to C/COM terminals and pins cabinet ground distributed on the economizer board. Johnson Controls Ducted Systems...
  • Page 57 24 VAC common/0-10 VDC negative for the air Connects through circuit trace to 24V~ IN pin COM monitoring station sensor 24 VAC hot supplied for the building pressure 24V~ Connects through circuit trace to 24V~ IN pin HOT sensor Johnson Controls Ducted Systems...
  • Page 58: Start-Up (Cooling)

    Verify proper system pressures. Set the room thermostat to the off position. Measure the temperature drop across the evaporator coil. Turn unit electrical power on. Johnson Controls Ducted Systems...
  • Page 59: Troubleshooting

    10.7 300 Cfm/Ton 12.5 80/72 14.3 11.1 300 Cfm/Ton 12.6 75/62 14.1 11.3 400 Cfm/Ton 12.7 80/62 14.2 11.2 400 Cfm/Ton 12.7 80/67 14.2 11.1 400 Cfm/Ton 12.7 80/72 14.3 11.2 400 Cfm/Ton 12.7 75/62 14.1 Johnson Controls Ducted Systems...
  • Page 60: Zz08 Charging

    Compr. amps Indoor Db/Wb 300 Cfm/Ton 80/62 10.4 300 Cfm/Ton 80/67 10.6 300 Cfm/Ton 80/72 10.8 300 Cfm/Ton 75/62 10.4 400 Cfm/Ton 80/62 10.4 400 Cfm/Ton 80/67 10.5 400 Cfm/Ton 80/72 10.7 400 Cfm/Ton 75/62 10.4 Johnson Controls Ducted Systems...
  • Page 61: Zz09 Charging Table System 2

    11.0 300 Cfm/Ton 10.2 80/67 11.3 300 Cfm/Ton 10.4 80/72 11.6 300 Cfm/Ton 10.0 75/62 11.0 400 Cfm/Ton 10.0 80/62 11.0 400 Cfm/Ton 10.1 80/67 11.2 400 Cfm/Ton 10.2 80/72 11.3 400 Cfm/Ton 10.0 75/62 11.0 Johnson Controls Ducted Systems...
  • Page 62: Zz12 Charging Table System 2

    11.2 300 Cfm/Ton 12.7 80/72 14.2 11.1 300 Cfm/Ton 12.3 75/62 13.5 11.1 400 Cfm/Ton 12.3 80/62 13.5 11.2 400 Cfm/Ton 12.5 80/67 13.8 11.3 400 Cfm/Ton 12.7 80/72 14.1 11.1 400 Cfm/Ton 12.3 75/62 13.5 Johnson Controls Ducted Systems...
  • Page 63: Smart Equipment™ Control Board Navigation Components

    NOTE: For more in-depth sequence of operation of the Smart distributor. Equipment™ control, refer to the Smart Equipment™ Controls Sequence of Operation Overview LIT- Local LCD on Unit Control Board. 12011950. Mobile Access Portal (MAP) Gateway (Portable). • Source 1 P/N S1-JC-MAP1810-OP Johnson Controls Ducted Systems...
  • Page 64: Start-Up Sheet

    5834853-YIM-B-0320 Start-Up Sheet Johnson Controls Ducted Systems...
  • Page 65 5834853-YIM-B-0320 Johnson Controls Ducted Systems...
  • Page 66 5834853-YIM-B-0320 Johnson Controls Ducted Systems...
  • Page 67 5834853-YIM-B-0320 Johnson Controls Ducted Systems...
  • Page 68 5834853-YIM-B-0320 Johnson Controls Ducted Systems...
  • Page 69 Subject to change without notice. Printed in U.S.A. 5834853-YIM-B-0320 Copyright © 2020 by Johnson Controls, Inc. All rights reserved. Supersedes: 5834853-YIM-A-1119 York International Corporation 5005 York Drive Norman, OK 73069...