7.2 Hobs with push-buttons
On first connection to the electrical mains, an operating check will be carried out automatically
and all the indicator lights will come on for a few seconds.
7.2.1 Single plates
When not in use, all hob components will be switched off. If the symbol of any
push-button is pressed for a few seconds, the hob will switch on and the circular
sectors on the buttons indicating the plate controlled by each button will
illuminate.
The power level must be set within 30 seconds after the sectors light up;
otherwise the hob will switch off automatically.
To set the power level use the or push-buttons as follows:
1. press the
(0 appears on the display: meaning that the plate has been
switched on);
2. press the
(9 appears on the display: meaning that the plate is on at full
power);
3. At this point;
a. Pressing the symbol repeatedly regulates the plate's power setting
from the full power level (9) towards the lowest setting (1);
b. Pressing the symbol repeatedly regulates the plate's power setting
from the lowest power level (1) to the highest setting (9);
4. To switch off the plate, return the display reading to 0 by pressing the or
symbol repeatedly.
A "BEEP" of confirmation is heard whenever the or symbols are pressed.
7.2.2 Dual plates
Operation of plates with dual heating is different from that of those with single
heating. When they are switched on, two indicator lights illuminate beside the
number showing the power level, as shown in the diagram.
When not in use, all hob components will be switched off. If the symbol of any
push-button is pressed for a few seconds, the hob will switch on and the circular
sectors on the buttons indicating the plate controlled by each button will
illuminate.
The power level must be set within 30 seconds after the sectors light up;
otherwise the hob will switch off automatically.
To set the power level use the or push-buttons as follows:
1. press the symbol (0 appears on the display, meaning that the plate is on at
full power);
2. press the
symbol again (9 appears on the display, meaning that the small
plate is on at full power);
3. There are now two options available:
a.
press the symbol once (two markers illuminate beside the 9);
press the symbol to set the power of the dual plate.
or
b.
after proceeding as described in point 2, press the the
repeatedly to set the power of the small plate;
4. To switch off the plate, return the display reading to 0 by pressing the
symbol repeatedly.