Toshiba RAS-077SKV-E7 Service Manual page 21

Hide thumbs Also See for RAS-077SKV-E7:
Table of Contents

Advertisement

RAS-137SKV-E7 / RAS-137SAV-E6
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
ASM89D16UEZ
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
– 20 –
Temp. measurement
T1
TC
TA
Pulse Modulating
valve at liquid side
Strainer
TO
TE
NOTE :
FILE NO. SVM-15004
Max.
: 15m
Min.
: 2m
Chargeless : 15m
Refrigerant amount : 0.63kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

Hide quick links: