3. Water mode doesn't work (Non-Plumbing model type)
Symptom
1. Water mode doesn't work
1. Check for a loose connection
2. Check the resistance : pump motor, Valve, Lever S/W
51
Check Point
Main PCBA
Lever S/W
CON4
pin ~ 6
pin
5
th
th
Not Pushing
Sub PCBA
LEVER S/W
Pushing
CON 1
4
pin ~ 12
pin
th
th
Pushing
Pushing
2
CON
5
pin ~ 6
pin
th
th
Pushing
Pump Motor
Water Valve
Copyright © 20 21 LG Electronics Inc. All rights
reserved. Only training and service purposes.
CON4
CON2
CON1
Voltage [V]
11.5~12.5
Pushing
0~2
Water
Voltage [V]
21.6~26.5
Not
0~2
0~2
Not
3.5~5
Resistance [ohm]
2.8ohm
1520~1680ohm