LG LRSXC2706 Series Service Manual page 45

Table of Contents

Advertisement

Troubleshooting
Defrost Heater Error
( F dH)
1
Check the Door gasket .
Is door gasket damaged?
No
2
Check the Defrost control part.
(2) Is Defrost Heater resistance
39 ~ 44 ?
Yes
3
Check the Defrost control part.
Is Defrost Sensor resistance
22kΩ↑ or OFF?
22kΩ
4
Input Test 2 Mode
(Push the button 2 times)
Replace the
Yes
Check the Heater Voltage.
Door gasket
Is voltage 112~116V?
Change
Fuse-M
No
5
Input Test 1 Mode
(Push the button 1 time)
Check the Heater Voltage.
Is voltage 0V?
Replace
OFF
product
6
Explain to customer
46
TEST MODE 2
Voltage [V]
CON9
7
nd
pin ~ 13
th
pin
Yes
TEST MODE 1
Voltage [V]
CON9
nd
th
7
pin ~ 13
pin
Yes
Copyright © 20 21 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Replace
NO
Main PCB
120V
Replace
No
Main PCB
0V

Hide quick links: