Troubleshooting
Condenser Fan Error ( E CF)
1
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
2
Check the fan rotating.
Does fan rotate?
Fan Motor
Yes
Go to 4
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Fan Motor
4
Is Fan Motor voltage 10 ~ 12 V?
5 Check the Fan Motor voltage
No
Go to 3
Is Fan PWM voltage 2~4.5V ?
5 Check the Fan Motor voltage
Is Fan Feed Back voltage 0V,5V ?
Change the
Yes
Fan motor
6 Explain to customer
50
Check the Fan Motor voltage
TEST MODE 1
Voltage [V]
CON3
10 ~ 12 V?
9
th
pin ~ 12
th
pin
Yes
TEST MODE 1
Voltage [V]
CON3
2~4.5 VDC
9
th
pin ~ 11
th
pin
Yes
TEST MODE 1
Voltage [V]
CON3
Not 0V, 5V
th
th
9
pin ~ 10
pin
No
Copyright © 20 21 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Replace
No
Main PCB
Replace
No
Main PCB
Change the
Yes
motor

Hide quick links: