OPERATING INSTRUCTIONS

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully
open.
3. This gas log set is equipped with an ignition
device (piezo) which automatically lights the
pilot. If piezo ignitor does not light the pilot,
see instructions for Match Lighting below.
4. Turn gas control knob clockwise
"OFF" position, and turn ON/OFF switch to
"OFF" position.
5. Wait (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information label. If you don't smell gas, go
to next step.
6. From "OFF" position, turn the gas control knob
counterclockwise
in control knob for 5 seconds.
Millivolt Pilot
FP2859
millivolt pilot flame
1. Turn control knob clockwise
tion to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to "OFF" posi-
tion.
1. Remove any items necessary for easy access
to the pilot (for example: logs, screens, etc.).
2. Follow appropriate lighting instructions found
previously. Instead of pushing and releasing the
piezo button, light a match and hold the flame to
the end of the pilot and ignite the pilot.
Majestic • VDY 24/18, VDY 30 Gas Log Heater Installation/Owner's Manual • 32D1999 • Rev A • 08/16
to the
to "IGN" position. Push

TO TURN OFF GAS TO HEATER

to "OFF" posi-

MATCH LIGHTING INSTRUCTIONS

"Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire
Wait 30 seconds before readjusting the
heater when the control knob has been
turned down to a lower setting.
7. With the control knob pushed in, push in and re-
lease the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further
60 seconds to prevent the flame detector from
shutting off the gas while the probe is warming
up. Release the control knob.
9. Turn gas control knob counterclockwise
to the "ON" position.
10.After the pilot has been lit for one minute, the
burners can be turned on. Turn the ON/OFF
switch to "ON" position.
11.If the gas logs will not operate, follow the instruc-
tions To Turn Off Gas To Heater and call your
service technician or gas supplier.
Control Knob
FP2861
millivolt control knob
3. If applicable: Turn off all electric power to the
heater.
3. After control knob has been released and pilot
stays lit, re-install any items that were removed
for pilot access.
4. Call a qualified service technician for repair or
replacement of the piezo ignitor.