Terminal Module Options; Option A3E - HP VXI 75000 C Series User's And Scpi Programming Manual

Algorithmic closed loop controller
Table of Contents

Advertisement

Terminal Module Options

Option A3E

Chapter 2
Besides the standard Terminal Module with push-in connectors, the The HP E1415
can be ordered with the following two options. One option (Option A3F) allows
connection to an HP E1586 Rack Mount Terminal Panel and the other option (A3E)
allows direct connections to the HP E1415 A/D Module's Faceplate using
connectors.
Option A3E can be ordered if a crimp-and-insert terminal module is desired. This
allows you to crimp connectors onto wires which are then inserted directly into the
E1415's Faceplate connector. Refer to the pin-out diagram in Figure 2-19 on page
53 to make the connections. The crimp-and-insert connector is shown in Figure 2-17.
Note
The pinout numbering on the crimp connector may not agree with the
pinput numbering on the HP E1415's faceplate connector. Use the pin
numbering on the faceplate connector to wire the crimp connector.
Figure 2-17. Crimp-and-Insert Connector
Field Wiring
49