Description:
The DRC-4720 is a DIN Rail mount, self-contained DC
powered module designed for load cell, strain gage, or
single ended use. The DRC-4720 contains a precision
instrumentation amplifier, filtered output and a built-
in 10V excitation supply capable of driving a 350 ohm
bridge. The 0 to 30mV input range makes it compatible
Features:
Low Cost
Din Rail Mount
Load Cell or Single Ended Application
4-20mA
Amplifier
Gain
Input for a 20mA Output
Linearity: 4 to 20mA Out
Temperature Coefficient
Input Offset Voltage
Temperature Coefficient
Common Mode Voltage
Common Mode Rejection - DC
Input Noise
0.1Hz to 10Hz
Output
Output Range
Compliance Voltage
Loop Resistance
Frequency Response
2 Pole Filter
Total RMS Gain
Temperature Coefficient
M4739/0109
10mV to 30mV
0.05% / ºC
0.7μV / ºC
0 to +5 Volts
0.3μV pp Typ
4 to 20mA
5.5V Max
250Ω Max
DC to 10Hz
0.007% / ºC
with most strain gage based load cell or pressure
transducer outputs. The DRC-4720 provides an output of
4 to 20mA. Connections are made via easily accessible
screw clamp terminal blocks. Zero and Span adjustment
potentiometers are located externally as well for easy
access.
Bridge Supply
Fixed Output
Temperature Coefficient
±0.01
Load Current
Power Requirements
±70μV
Voltage
Input Current (1 - 350 Ohm Bridge)
Environment
100 dB
Operating Temperature
Storage Temperature
Size
Size
(Not including Universal Foot for
standard DIN EN Rails)
Weight
Agency Approval
UL, CE
+10V ±1.5%
0.05% / ºC
30mA Max
18 to 26 Volts
55 mA
0ºC to +55ºC
-40ºC to +80ºC
1.65"H x 1.06"W x 3.78"L
(42 x 27 x 96mm)
3 oz. (85g)
UL508, UL1604, CE
Pending

Advertisement

loading

Summary of Contents for Omega DRC-4720

  • Page 1 Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Description: The DRC-4720 is a DIN Rail mount, self-contained DC with most strain gage based load cell or pressure powered module designed for load cell, strain gage, or transducer outputs. The DRC-4720 provides an output of single ended use.
  • Page 2 DRC-4720 BRIDGE INPUT SIGNAL CONDITIONER FULL BRIDGE CONNECTION SINGLE ENDED Getting Started with the Model DRC-4720 1. Hook Up Procedure C. Connect a current meter across the output, pins 5 and 6. A. Connect the +out of the load cell to the +INPUT, pin 3.
  • Page 3 DRC-4720 BRIDGE INPUT SIGNAL CONDITIONER Mechanical tolerances unless otherwise noted: X.XX dimensions ±0.020 inches X.XXX dimensions ±0.005 inches TERMINAL FUNCTION TERMINAL FUNCTION SW1-1, SW1-2 GAIN SWITCHES +OUTPUT SPAN SPAN ADJUSTMENT +EXCITATION - EXCITATION +24V - INPUT ZERO ZERO ADJUSTMENT +INPUT...
  • Page 4 European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.