Panasonic CU-RE9NKX Service Manual page 36

Hide thumbs Also See for CU-RE9NKX:
Table of Contents

Advertisement

Power Button pressed
D
PIPING
C
TEMP.
(COOLING)
B
A
FAN SPEED
( rpm)
Correction
Factor( )
OFF
2. For Heating mode:
Power Button pressed
D
C
PIPING
PIPING
TEMP
TEMP.
B
(HEATING)
(COOLING)
A
FAN SPEED
( rpm)
Correction
Factor( )
OFF
Note: The value of A, B, C, D will change according to the indoor temperature.
12.3.5 Automatic Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to
four minutes after power supply resumes.
12.3.6 Indication Panel
LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF
Note:
If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timer
sampling.
● If Timer LED blinks, there is an abnormal operation occurs.
12.3.7 Timer control
Delay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting
time. This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set
time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30
seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation
Min.5'
Fast Cooling
1130 (Max)
Shi
45 seconds
20 '
-1.67
-1.00
ON
Min.5'
Fast Heating1
1270 (Max)
Shi
45 seconds
+1.00
+2
20 '
ON
TIMER
Orange
Timer setting ON
Timer setting OFF
Cooling, Soft Dry
730 (Min.)
20 '
20 '
20 '
-0.25
Heating
940 (Min.)
20 '
20 '
+0.25
20 '
QUIET
GREEN
Quiet mode ON
Quiet mode OFF
36
AUTO
+0.25
AUTO
+0.25
POWERFUL
RED
Powerful mode ON
Powerful mode OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-re9nkxCs-re12nkxCu-re12nkxCs-re15nkxCu-re15nkx

Table of Contents