The KLK-E6 keypad has an External IR Receiver In
terminal for connecting an external IR Receiver such
as the Russound 858, SaphIR 862 Eye, or SaphIR
860 Phantom.
Use 2 twisted pair wire with one pair connecting
GND (GROUND) and IR (SIGNAL) and the other
pair connecting ST (STATUS) and V+ (+12VDC). Do
not connect the shield to the IR receiver terminals.
If using an external IR receiver, you can avoid
"double" receipt of IR signals sent from a remote by
disabling the keypad's IR receiver. This is disabled in
the Installer options menu on the keypad. See screen
example at right.
Russound KLK-E6 Installation Manual
KLK-E6 ExTERNAL IR CONNECTION
Shared
Russound 858
IR receiver (back)
Disable Keypad IR
DO NOT
CONNECT
SHIELD
2 twisted
pair cable
Shield wired
to ground
>