IMPORTANT
• We recommend an additional standard 120 V/15 A receptacle for service tools,
such as a laptop computer or vacuum that may be used when servicing or
configuring the machine.
• The imageRUNNER ADVANCE 8500 III Series main unit requires a dedicated
single-phase 120V/20 A NEMA 5-20 receptacle for proper operation. Canon
U.S.A., Inc. strongly recommends dedicated and properly grounded receptacles
be provided for the optional accessories. Do not use extension cords. The
ground connection serves to provide the internal electronics with a reference
voltage. Faulty or poor ground sources will cause this reference voltage to fall
into a range that no longer serves as a reliable reference voltage. The internal
logic and programming of the imageRUNNER ADVANCE 8500 III Series will
not perform reliably because there is an insufficient difference between the
internal operating signal voltages and the poor ground reference signal. A
qualified electrician can measure and provide the ground source that the
imageRUNNER ADVANCE 8500 III Series or any computer controlled office
equipment requires.
• Before installation, confirm that all necessary receptacles are available.
Version 1
imageRUNNER ADVANCE 8500 III Series Customer Expectations Document
imageRUNNER ADVANCE 8500 III Series Customer Expectations Document