INTERIOR VENTILATOR KITS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer or your dis-
tributor.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with an additional speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
WARNING
TO REDUCE THE RISK OF A COOKTOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. If the flames do not go out immediately, EVACU-
ATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-
lent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you al-
ready know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Your ventilator motor has a thermal overload which will auto-
matically shut off the motor if it becomes overheated. The mo-
tor will restart when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
4. Please read specification label on product for further informa-
tion and requirements.
MODELS • 804702 • 805087

Advertisement

loading

Summary of Contents for Wolf 804702

  • Page 1 MODELS • 804702 • 805087 INTERIOR VENTILATOR KITS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Never leave surface units unattended at high settings. Boilovers 1.
  • Page 2 MODELS • 804702 • 805087 MODEL 804702 INSTALLATION MODEL 805087 INSTALLATION For use with Wolf 48"–66" wide x 18" tall Wall For use with Wolf 34"–58" wide x 12" tall Liner Hoods. Hoods. Slide TAB on ventilator top plate through RECTANGULAR SLOT Slide TAB on ventilator top plate through RECTANGULAR SLOT on underside of VENTILATOR MOUNTING PLATE (provided).
  • Page 3 MODÈLES MODELS • 804702 • 805087 KITS INTÉRIEURS DE VENTILATEUR AVERTISSEMENT AVERTISSEMENT AFIN DE DIMINUER LES RISQUES D’INCENDIE POUVANT SE AFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTRO- DÉCLENCHER SUR LA SURFACE DE CUISSON: CUTION OU DE BLESSURES, SUIVEZ CES DIRECTIVES: 1.
  • Page 4 INSTALLATION À utiliser avec les hottes murales Wolf de 121,9 cm À utiliser avec les gaines de hotte Wolf de 86,4 cm à 167,7 cm (48" à 66") de largeur X 45,7 cm (18") à 147,3 cm (34" à 58") de largeur X 30,5 cm (12") de hauteur.

This manual is also suitable for:

805087