Horizontal Obstructions; Sideways Flue Diverter - All Models Except Reu-Vcm; Multiple Appliance Installations - Rinnai Infinity 26 Touch Operation & Installation Manual

Gas continuous flow water heater
Hide thumbs Also See for Infinity 26 Touch:
Table of Contents

Advertisement

Horizontal Obstructions

and obstruction facing the terminal.
MINIMUM OBSTRUCTION
HEIGHT IS TO BE NO LESS
THAN TOP OF APPLIANCE
the full front cover height of the appliance (for appliance dimensions, refer to "Table 3. Appliance Dimensions -
There MUST be NO partial obstructions to the front cover of the appliance or any other parts
of the appliance casing. This will avoid the appliance failing to operate under windy conditions.
IMPORTANT

Sideways Flue Diverter - All models except REU-VCM

CONTROL BOARD DIPSWITCH SETTING (NOT REU-VCM):
The installer MUST follow the Sideways Flue Diverter instructions of the "Commissioning Check
WARNING
List" provided on the front cover of the appliance and the "Commissioning Instructions" located
in the inside the appliance front cover.
When delivered ex-factory ALL the
switches of the control board dipswitch
are set to OFF (left position).
the installer MUST set switches SW1
and SW3 to ON (right position) ONLY.
Improper setting of the switches will cause the appliance to operate incorrectly.

Multiple Appliance Installations

of the same model are installed on the same vertical
Under these conditions appliances can abut each other
For appliance dimensions, refer to "Table 3. Appliance
Universal Water Controller" on page 34.
Rinnai
500mm
MUST also
SW1 (OFF)
SW2 (OFF)
SW3 (OFF)
SW4 (OFF)
Factory Default
20
MUST 'obstruct'
DipSW
SW1 (ON)
SW2 (OFF)
SW3 (ON)
SW4 (OFF)
Sideways Flue Diverter
DipSW
HW_CF OIM