United States Stove HOTBLAST 1500 Owner’s Instruction And Operation Manual

United States Stove HOTBLAST 1500 Owner’s Instruction And Operation Manual

Coal only

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Number:
COAL ONLY
Report Number: F21-692
CERTIFIED TO UL 391-2006 (R2019)
DO NOT USE THIS FURNACE IN A MOBILE HOME OR TRAILER.
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
This heater is not certified for wood burning.
Use of any wood fuel is a violation of federal
regulations.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
1500
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
851486Q - 0601K
Ph. 800-750-2723

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove HOTBLAST 1500

  • Page 1 Use of any wood fuel is a violation of federal cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov regulations. THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with customerservice@usstove.com your records for any claims. © 2021 United States Stove Company...
  • Page 3: Installation Checklist

    Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2021 United States Stove Company...
  • Page 4 SHOULD BE PERFORMED PRIOR TO EACH HEATING DO NOT BURN GARBAGE, GASOLINE, DRAIN OIL, SEASON. IF USING AN EXISTING CHIMNEY, IT MUST OR OTHER FLAMMABLE LIQUIDS. BE INSPECTED PRIOR TO THE INSTALLATION OF YOUR NEW WOOD STOVE. © 2021 United States Stove Company...
  • Page 5: Assembly And Installation

    Note: Slotted holes are for adjustment of handle. Adjust handle until some pressure is required 9. Check operation of shaker grates with grate handle to lock feed door during firing sequence. before operating furnace. © 2021 United States Stove Company...
  • Page 6: Optional Equipment

    It uses a standard 16 x 20 x 1 filter (NOT INCLUDED) to reduce the amount of dust particles from being transferred thru you duct work system. © 2021 United States Stove Company...
  • Page 7: Installation

    It is possible that both systems will operate simultaneously. It is recommended that for the most efficient use of this furnace, that it be fired as much as possible in order to © 2021 United States Stove Company...
  • Page 8: Masonry Chimney

    Have the chimney cleaned 18" before the furnace is installed and operated. When NON-COMBUSTIBLE connecting the furnace through a combustible wall to FLOOR a masonry chimney, special methods are needed as NON-COMBUSTIBLE © 2021 United States Stove Company FLOOR...
  • Page 9: Combustible Wall Chimney Connector Pass-Throughs

    Support the wall thimble, and cover its opening with a liner. 24-gauge minimum sheet metal support. Maintain the © 2021 United States Stove Company...
  • Page 10: Chimney Connector

    Male Part Downwards Flow NOTES: Connectors to a masonry chimney, excepting Direction of Flue method B, shall extend in one continuous section through 3 screws Gases the wall pass-through system and the chimney wall, to © 2021 United States Stove Company...
  • Page 11 This is a furnace, not a free standing stove. You must direct heated air from 8" outlets away from the furnace, or it will not function properly. This installation must be done by a qualified heating equipment installer. © 2021 United States Stove Company...
  • Page 12: Add-On Installation

    INSTALLATION METHODS OF INSTALLATION. CENTRAL INSTALLATION ADD-ON INSTALLATION © 2021 United States Stove Company...
  • Page 13 TO EXISTING PLENUM DUCT WORK 2” min. COLLECTOR CLEARANCE WARM AIR COLD AIR RETURN COLD AIR RETURN FURNACE PLENUM ANTI- BACKDRAFT FLAPPER EXISTING FURNACE EXISTING FURNACE SOLID FUEL FURNACE SOLID FILTER BOX FUEL FURNACE © 2021 United States Stove Company...
  • Page 14 CLEARANCE EXISTING OIL, ELECTRIC, COLD AIR OR GAS RETURN FURNACE FURNACE PLENUM SOLID FUEL FURNACE SOLID FUEL FURNACE 2” min. EXISTING CLEARANCE FURNACE EXISTING OIL, ELECTRIC, OR GAS FRONT VIEW FURNACE SOLID FUEL FURNACE © 2021 United States Stove Company...
  • Page 15: Operation

    After loss of power remove the filter if provided and do remove excess ashes. Leave an ash bed approximately not expect to keep home at normal temperatures. 1 inch deep on the firebox bottom to help maintain a © 2021 United States Stove Company...
  • Page 16 4. If the chimney is operating too cool, water will condense in the chimney and run back into the furnace. Creosote formation will be rapid and may © 2021 United States Stove Company...
  • Page 17: Wiring Diagram

    This furnace has a painted outside jacket, which is SHORT PERIOD OF TIME. ONCE THIS BURN-OFF durable, but it will not stand rough handling or abuse. HAS OCCURRED, IT SHOULD NOT REOCCUR. WIRING DIAGRAM © 2021 United States Stove Company...
  • Page 18: Troubleshooting

    Ashes, if allowed to accumulate in the ash pit, will not allow passage of the required air for combustion. Keep ash pit clean. This furnace is not to be used with an automatic stoker unless so certified. © 2021 United States Stove Company...
  • Page 19 Adjust the stove pipe damper to the fire is WELL ESTABLISHED add coal to the center reduce the draft on the fire. With anthracite there will be of the firebox forming the cone. Burning in this fashion © 2021 United States Stove Company...
  • Page 20: How To Order Repair Parts

    Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2021 United States Stove Company...
  • Page 21: Repair Parts

    REPAIR PARTS © 2021 United States Stove Company...
  • Page 22 Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2021 United States Stove Company...
  • Page 23 Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2021 United States Stove Company...
  • Page 24: Service Record

    Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2021 United States Stove Company...

Table of Contents