Terminating chop
Press the LOCK (CHOP) button.
Adjusting the chop interval
Turn the selector knob. Turning it clockwise makes the
interval longer, and counterclockwise makes it shorter.
Preventing Source Switching for
Destinations (Protect)
When protection is set, switching of the source for the
protected destination is disabled.
PROT button
Setting protection
1
Select a destination to be protected.
2
Press the PROT button.
The PROT button lights up green, and protection mode is
activated. Switching of the crosspoint for the destination
specified in step 1 is disabled.
Releasing protection
Protection can be released only on the unit which the
protection was set. Normally, the protection on other units
cannot be released.
1
Select a destination whose protection is to be
released.
2
Press the PROT button.
The PROT button lamp turns off, and the protection is
released.
Protection set on another remote control
panel
If you select a destination for which protection has been set
on another remote control panel, the pressed button and the
PROT button light up red.
Note
When [Protect Mode] is set to [Occupy] in the web menu,
switching is possible without releasing the protection, if
protection is set, on the currently operating remote control
panel (switching is not possible on other remote control
panels when protected). Set [Protect Mode] to [Protect] for
normal operation.
PROT button (lit red)
Destination selection buttons
Selection buttons
Preventing Accidental Operation
(Lock)
When the panel is locked, accidental switching of crosspoints
is avoided.
When the MKS-R3210/R1620 is locked, "Lock" and the IP
addresses of LAN1 and LAN2 appear in sequence in the
preset display window.
On the MKS-R1630, the
status display window. Press the STATS,DISP button to
display the network settings and version information in
sequence.
LOCK (CHOP) button
Locking the panel
1
Press the LOCK (CHOP) button.
The LOCK (CHOP) button lights up red (lock mode). All
buttons other than the LOCK (CHOP) button are
disabled.
Releasing the lock
1
Press the LOCK (CHOP) button.
The LOCK (CHOP) button lamp turns off, and lock mode
is released.

Monitoring Destinations

When you specify a destination to be monitored using IP Live
System Manager or the web menu, the control destination
automatically selects the same source as the destination you
wish to monitor when the MONI button is pressed.
1
Set the destination you want to monitor in
[Destination Monitoring] in IP Live System Manager.
2
Set the MONI button configured for the destination
you want to monitor in the web menu.
3
Press the MONI button.
The source for the pressed control destination is linked to
the source of the destination you want to monitor.
MONI button
23
(lock icon) appears in the