Fujitsu ADUH09LUAS1 Service Manual page 67

Hide thumbs Also See for ADUH09LUAS1:
Table of Contents

Advertisement

2-11. E: 3A. Indoor unit communication circuit (wired remote
controller) error
→ired remote
Indicator
controller
→ired remote controller (2-wire)
Detective actuator
Indoor unit controller PCB circuit
Forecast of cause
Check point 1. Check the connection of terminal
After turning off the power supply, check and correct the followings
Indoor unit - Check the connection the communication PCB and the main PCB
Check Point 2 : Replace the communication PCB
If the Check point 1 is ok, replace the communication PCB
Check Point 3 : Replace the main PCB
If condition is doesn't change, replace the main PCB
2-11. E: 3A. Indoor unit communication circuit (wired remote controller) error
Error code
End
Detect the communication error of microcomputer and
communication PCB.
Communication PCB defective
Indoor unit main PCB defective
- (03-15) -
E: 3A
2. Troubleshooting with error code