LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or
anything that will obstruct the flow of combustion and ventilation
air.
3. On carpet. Floor MUST be solid with a maximum slope of 1 inch
(2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST
be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same
closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A SOLID
DOOR.
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
CLOSET DOOR
If an under counter* installation is desired, the dryer MUST have a top sheet kit
installed, P/N 131629100. Kit is available from an authorized parts distributor.
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
60 SQ. IN.
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
(387.1 SQ. CM)
NOTE: Under counter and stack models - 0 inches (0 cm)
for sides, rear, and top.
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
UNDER COUNTER INSTALLATION
*Custom-sized countertop is required.
4. A minimum of 120 square inches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, is required.
Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the
full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
FRONT
Alcove or
Under counter 0 (0 cm)
Closet
1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet door ventilation required: 2 louvered openings each 60
square inches (387 square centimeters) — 3 inches (7.6 cm)
from bottom and top of door.
THIS DRYER MUST BE EXHAUSTED OUTDOORS.
5. The following illustrations show minimum clearance dimensions
for proper operation in a recess or closet installation.
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
15" (38.1 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
4
SIDES
REAR
TOP
0 (0 cm) 0 (0 cm) 15 (38.1 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
1" (2.54 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)