Electrical Connection - Parker MGV Series Technical Manual

High speed motors
Hide thumbs Also See for MGV Series:
Table of Contents

Advertisement

4.3. Electrical connection

Warning : Check that the power to the electrical cabinet is safely off prior to
make any connections.
Warning : The wiring must comply with the drive commissioning manual,
with recommended cables, the standard and the local regulations
Warning : The high-speed motor must be grounded by connecting to an
unpainted section of the motor.
Danger: After 15 days, check all tightening torques on cable connection.
Bad connections can lead to overheating and fire.
Please, read §3.7 "Electrical connection" to have information about cable
recommendations.
A lot of information are already available in the drive documentations.
The motor has to be connected to the drive in accordance with its commissioning manual.
Colour codes are as follow:
Signal
U
V
W
Earth
Thermal sensor KTY84-130 (+) Brown
Thermal sensor KTY84-130 (-)
Thermal protector PTC 150°C
Thermal protector PTC 150°C
70 - PVD3627-August 2011
Colour
black
white
red
green/yellow
White
yellow
yellow

Advertisement