3.1.6.
Current limitation at stall conditions (i.e. speed < 3 rpm)
Recommended reduced current at speed < 3 rpm:
2
=
≅
I
*
I
0.80
reduced
0
3
Warning: The current must be limited to the prescribed values. If the
nominal torque has to be maintained at stop or low speed (< 3 rpm),
imperatively limit the current to 80% of I
speed), in order to avoid an excessive overheating of the motor.
Please refer to the drive technical documentation for any further
information and to choose functions to program the drive.
*
I
0
24 - PVD3627-August 2011
(permanent current at low
0