Cooling; General Recommendations - Parker MGV Series Technical Manual

High speed motors
Hide thumbs Also See for MGV Series:
Table of Contents

Advertisement

3.5. Cooling

In compliance with the CEI 60034-1 standards:

3.5.1. General recommendations

Danger: The cooling system has to be operational when the motor is
running or energized.
Danger: The Inlet temperature and the water flow have to be monitored
to avoid any damage.
Caution: When motor is not running, the cooling system has to be
stopped 10 minutes after the motor shut down to avoid condensation.
Caution: Condensation and risk of rust may occur when the
temperature gradient between the air and the water becomes
significant.
Caution: the ambient air temperature shall not exceed 40°C in the
vicinity of the motor flange.
Danger: If the water flow stops, the motor can be damaged or
destroyed causing accidents.
50 - PVD3627-August 2011

Advertisement

Table of Contents
loading

Table of Contents