INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE
WARNING
TASK FORCE TIPS, INC.
MADE IN USA • www.tft.com
©Copyright Task Force Tips, Inc. 2016
MANUAL:
Understand manual before use. Operation of this device without understanding the manual
and receiving proper training is a misuse of this equipment. Obtain safety information at
www.tft.com/serial-number
OPERATING RANGE:
Pressure Max 300 PSI (20 bar)
Pressure Min Full Vac.
NFPA 1962 Test Pressure
300 PSI (21 bar)
Six seconds from open to close
meets NFPA 1901
slow close requirement.
Low Profi le
Ball Intake Valve
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 • 219-462-6161 • Fax 219-464-7155
LIA-212 December 8, 2016 Rev03

Advertisement

Table of Contents
loading

Summary of Contents for Task Force Tips Low Profile Ball Intake Valve

  • Page 1 Six seconds from open to close meets NFPA 1901 slow close requirement. TASK FORCE TIPS, INC. 3701 Innovation Way, Valparaiso, IN 46383-9327 USA 800-348-2686 • 219-462-6161 • Fax 219-464-7155 MADE IN USA • www.tft.com ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 2 6. Failure to follow these guidelines may result in death, burns or other severe injury. Fire and Emergency Manufacturers and Service Association FEMSA P.O. Box 147, Lynnfi eld, MA 01940 • www.FEMSA.org ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 3: Table Of Contents

    9.1.2 RELIEF VALVE TEST 9.1.3 SHUTOFF VALVE 9.1.4 RECORDS 9.2 CRANKSHAFT OVERRIDE & REPLACEMENT 9.2.1 CRANKSHAFT OVERRIDE 9.2.2 DIAGNOSIS 9.2.3 CRANKSHAFT REPLACEMENT 10.0 REPAIR 11.0 ANSWERS TO YOUR QUESTIONS 12.0 INSPECTION CHECKLIST ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 4: Meaning Of Signal Words

    Use with salt water is permissible provided the valve is thoroughly cleaned with fresh water after NOTICE each use. The service life of the valve may be shortened due to the effects of corrosion and is not covered under warranty. ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 5: General Information

    Use with salt water is permissible provided valve is thoroughly cleaned with fresh water after each use. The service life of the valve may be shortened due to the effects of corrosion and is not covered under warranty. ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 6: Installation

    If your application of this product requires drafting, you may need a suction gasket. Please call 1-800-348-2686 to receive a free suction gasket by mail. Part Numbers: 4” STORZ - item # A4216, 5” STORZ - item # A4221, 6” STORZ - item #A4273 ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 7: Use

    LDH valved appliances may be equipped with a pressure relief valve that can be set to any pressure between 90 and 300 psi. Its function is to protect the pump and supply hose from excess pressure. See LIA-202 Pressure Relief Valve Instructions for Safe Operation and Maintenance. ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 8: Setting Relief Valve Pressure

    This device may be equipped with a suction screen to catch debris larger than 3/8” diameter in the waterway. To add or replace a suction screen, order TFT part #A1410-KIT for the 4.5” waterway, and TFT part #A1411-KIT for the 5.0” waterway. See Section 5.4 for suction screen pressure loss. ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 9: Exploded Views And Parts Lists

    GEARBOX COVER A1507 MODEL NUMBER LABEL A1303 LABEL LOW PROFILE BIV A1315 1/4-20 X 3/4 SOCKET HEAD SCREW VT25-20SH750 DRAIN VALVE SUBASSEMBLY SEE SECTION 6.3 PRESSURE RELIEF VALVE SUBASSEMBLY A1758 ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 10: Side B Options Exploded Views And Parts Lists

    PLASTIC STRIP A1292 A1291 A1291 CUP SEAL A1597 A1596 A1596 LOCK-OUT SCREW A1294 A1294 VB.437 COUPLING A4124 A4125 A4289 MATE A4730 PLASTIC STRIP A1291 CUP SEAL A1596 BALL VB.437 ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 11: Air Vent/Drain [B] Exploded View And Parts List

    7.0 TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Leaks Debris or damage in seal area Clean out debris If it is not debris it will need to be returned for service ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 12: Warranty

    8.0 WARRANTY Task Force Tips, Inc., 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA (“TFT”) warrants to the original purchaser of its Low Profi le Ball Intake Valve (“equipment”), and to anyone to whom it is transferred, that the Low Profi le Intake Valve series includes a 5 year warranty against manufacturing defects and corrosion affecting the valve’s operational performance.
  • Page 13: Maintenance

    10. Date of each service test and service test results 11. Damage and repairs, including who made the repairs and the cost of repair parts 12. Reason removed from service ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...
  • Page 14: Crankshaft Override & Replacement

    5. If crankshaft is able to rotate, cycle the valve several times from open to closed to determine whether the crankshaft binds at any place between the travel stops. If crankshaft binds, consult Task Force Tips Service Department to determine the appropriate repairs.
  • Page 15: Repair

    Any returns should include a note as to the nature of the problem and whom to reach in case of questions. Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for damage to equipment or injury to personnel that is a result of user service.
  • Page 16: Inspection Checklist

    Operating an appliance that fails any of the above inspections is a misuse of this equipment. 3701 Innovation Way, Valparaiso, IN 46383-9327 USA TASK FORCE TIPS, INC. 800-348-2686 • 219-462-6161 • Fax 219-464-7155 MADE IN USA • www.tft.com ©Copyright Task Force Tips, Inc. 2016 LIA-212 December 8, 2016 Rev03...