Furuno TZT16F Installation Manual page 46

Multi function display
Hide thumbs Also See for TZT16F:
Table of Contents

Advertisement

3. HOW TO SET UP THE EQUIPMENT
[Initial Setup] menu - [CALIBRATION]
Menu item
[Heading]
Offset heading data.
[Speed Through
Calibrate speed data. Enter amount in percentage.
Water]
[Wind Speed]
Offset wind speed data. Enter amount in percentage. -50% to +50%
[Wind Angle]
Offset wind angle data.
[Sea Surface
Offset sea surface temperature data.
Temperature]
[Initial Setup] menu - [DATA DAMPING]
Menu item
[COG & SOG]
[Heading]
[Speed Through Water]
[Wind Speed & Angle]
[Rate of Turn]
[Initial Setup] menu - [FUSION]
Menu item
[Connect to Fusion]
[Fusion Auto Volume]
[Minimum Speed]
[Maximum Speed]
[Volume Increase]
[Initial Setup] menu - [BROWSER INSTALLATION]
Menu item
[FAX30 Browser]
[FA30 Browser]
[FA50 Browser]
[Initial Setup] menu (Other menu items)
Menu item
[Chart Master Device]
[System ID]
[IP Address]
[Quick Self Test]
[Certification Mark]
[Service]
[Update Network
Equipments]
[Event Input Configu-
ration]
3-8
Description
Description
Set data damping time. The lower the setting
the faster the response to change.
Description
Connects to your Fusion equipment.
Set to [ON] to allow the TZT16F unit to con-
trol the FUSION volume. Volume is adjusted
according to vessel speed.
Set the minimum speed threshold. Exceed-
ing this speed activates volume auto control.
Set the maximum speed threshold.
Set the amount of extra volume to output
when the vessel reaches the [Maximum
Speed] setting.
Description
Show the Facsimile Receiver FAX-30 display.
Show the AIS Receiver FA-30 display.
Show the AIS Receiver FA-50 display.
Description
Set to [ON] to use this unit as the master, [OFF] to use this unit as a slave.
The system ID for this device within the network.
IP address for this unit within the network.
Displays various details regarding the TZT16F unit, radar and fish finder.
Displays relevant certification for this equipment.
Requires login password. For the service technician.
For the service technician.
Set the function for the event switch.
Options (setting range)
-180.0° to +180.0°
-50% to +50%
-180° to +180°
-10°C to +10 °C
Options (setting range)
0 to 59 (seconds)
Options (setting range)
[ON], [OFF]
0.0 (kn) to 98.9 (kn)
0.1 (kn) to 99.0 (kn)
10% to 50%
Option (setting range)
Option (setting range)
[OFF], [Event], [MOB], [Ferry]