In this condition the control panel has different operations according to the chosen system configuration
( Traditional or Pre-Alarm, refer to Choice of the system configuration ) and programming performed upon
installation. Any detectors programmed with a delay, will create the alarms once the preset delay is
elapsed, during this time the control panel buzzer will emit an acoustic signal ( beep-beep-beep ).
24h tampering
Panic
Failure, Antiscanner
Supervision
Pre-Alarm
General alarm
Note:
- All the other signals are the same as the ones of the system disactivated, see previous table;
- All the other signals are the same as the ones of the system disconnected, see previous table;
- Each detector is self-disconnected after three alarms detected: the other detectors remain on. During the
connection system, all radio and hard wired detectors which are opened are displayed;
- The mains failure is displayed blinking in every system status.
In the event of control panel, detector or keypad tampering:
Acoustic signal emitted by the control panel internal sounder
Acoustic signal emitted by the AF53901R outdoor sounder
Enabling of outputs +SIR and +N
By enabling the panic alarm manually through the remote control or the keypad:
Acoustic signal emitted by the control panel internal sounder
3 minute-acoustic signal emitted by the AF53901R outdoor sounder
Enabling of outputs +SIR and +N
Enabling of PAN output for 15 seconds
In the event of an alarm:
Enabling of outputs +SIR and +N for 30 seconds
30 second- acoustic signal emitted by the control panel internal sounder
Enabling of ANOM output for 15 seconds
Traditional configuration
... ... ...
In the event of a general alarm:
3 minute-acoustic signal emitted by
the control panel internal sounder
3 minute-acoustic signal emitted by
the AF53901R outdoor sounder
Enabling of outputs +SIR and +N
Pre-alarm configuration
In the event of an alarm due to a
detector belonging to a zone configured
as an external zone:
3 minute-acoustic signal emitted by
the control panel buzzer ( beep-beep-
beep ) interrupted during the call
3 minute-low intensity acoustic signal
emitted by the AF53901R outdoor
sounder
In the event of an alarm due to a
detector
configured as an external zone :
3 minute-acoustic signal emitted by
the control panel internal sounder
3 minute-acoustic signal emitted by
the AF53901R outdoor sounder
Enabling of outputs +SIR and +N