Performance Data
Table 16. OAKE general data—cooling 12–20 tons high efficiency (continued)
Motor HP (kW), Standard–Oversized
Motor RPM, Standard–Oversized
Motor Frame Size, Standard–Oversized
Filters
Type Furnished
Number Size Recommended
Refrigerant Charge, lb of R-410A
Downflow
Table 17. OANE general data—cooling 30–40 tons high efficiency
Cooling Performance
Gross Cooling Capacity, Btu (kW)
Heating Performance
Gross Heating Capacity, Btu (kW)
CFM
Nominal cfm/AHRI rated cfm (m
Compressor
Number
Type
Outdoor Coil
Type
Tube Size—OD, in. (mm)
2
2
Face Area, ft
(m
)
Rows
FPI
Indoor Coil
Type
Tube Size—OD, in. (mm)
2
2
Face Area, ft
(m
)
Rows
FPI
Refrigerant Control
Drain Connection Size, in. (mm)
Outdoor Fan
Type
Number Used
Diameter, in. (mm)
Drive Type
No. Speeds
3
CFM (m
/h)
Number Motors
Motor HP (kW), per motor
Motor RPM
Indoor Fan
Type
Number Used
54
12 Tons Downflow
OAKE144A
1–5.0 (0.75–3.73)
1750–3500
Varies
Refer to
"OAU Filter Guide"
in
"Appendix," p. 68
See Nameplate
30 Tons Downflow
OANE360A
379,546 (111.23)
361,914 (106.07)
3
/h)
3750–7500 (2207–4414) 4375–8750 (2575–5150) 5000–10000 (2943–5886)
2
Scroll
High Performance
1/2 (12.7)
50 (4.65)
2
12
High Performance
1/2 (12.7)
22 (2.04)
4
12
TXV
1-1/4 (31.8)
Propeller
4
24 (609.6)
Direct Drive
1
26,000 (15,303)
4
1.0 (0.75)
1,140
Backward Inclined
1
15 Tons Downflow
17 Tons Downflow
OAKE180A
OAKE210A
1–5.0 (0.75–3.76)
1–7.5 (0.75–5.59)
1750–3500
Varies
Refer to
"OAU Filter
Refer to
Guide"
in
"Appendix,"
Guide"
p. 68
See Nameplate
See Nameplate
35 Tons Downflow
40 Tons Downflow
OANE420A
451,733 (132.39)
406,655 (119.18)
3
Scroll
High Performance
1/2 (12.7)
62 (5.76)
2
12
High Performance
1/2 (12.7)
28 (2.60)
4
12
TXV
1-1/4 (31.8)
Propeller
4
24 (609.6)
Direct Drive
1
26,000 (15,303)
4
1.0 (0.75)
1,140
Backward Inclined
1
20 Tons Downflow
OAKE240A
1–7.5 (0.75–5.59)
1750–3500
1750–3500
Varies
Varies
"OAU Filter
Refer to
"OAU Filter
in
"Appendix,"
Guide"
in
"Appendix,"
p. 68
p. 68
See Nameplate
OANE480A
491,044 (143.91)
450,153 (131.93)
3
Scroll
High Performance
1/2 (12.7)
62 (5.76)
2
12
High Performance
1/2 (12.7)
28 (2.60)
4
12
TXV
1-1/4 (31.8)
Propeller
4
24 (609.6)
Direct Drive
1
26,000 (15,303)
4
1.0 (0.75)
1,140
Backward Inclined
1 or 2
OAU-SVX01H-EN