Model Number Descriptions
Digit 32 — ERV Size
0
=
No ERV
4
=
4634
5
=
5856
6
=
6488
7
=
6876
8
=
74122
Digit 33 — Damper Options
0
=
100% OA 2-Position Damper
1
=
100% OA 2-Position Damper
w/RA 2-Position Damper
2
=
Modulating OA and RA Dampers
w/Economizer
Digit 34 — Filtration Options
A
=
Aluminum Mesh Intake Filters
(ALM)
B
=
MERV-8,30%, and ALM
C
=
MERV-13, 80%, and ALM
D
=
MERV-14, 95%, and ALM
E
=
MERV-8 30%, MERV-13 80%, and
ALM
F
=
MERV-8 30%, MERV-14 95%, and
ALM
G
=
MERV-8, 30%, and ALM, with
UVC
H
=
MERV-13, 80%, and ALM, with
UVC
J
=
MERV-14, 95%, and ALM, with
UVC
K
=
MERV-8 30%, MERV-13 80%,
ALM, and UVC
L
=
MERV-8 30%, MERV-14 95%,
ALM, and UVC
X
=
Special Filter Options
Digit 35 — Smoke Detector
(Factory-Installed)
0
=
No Smoke Detector
1
=
Supply Smoke Detector
2
=
Return Smoke Detector
3
=
Supply and Return Smoke
Detectors
Digit 36 — Electrical Options
0
=
Non-Fused Disconnect
A
=
Fused Disconnect Switch
B
=
Non-Fused Disconnect Switch
w/Convenience Outlet
C
=
Fused Disconnect Switch
w/Convenience Outlet
D
=
Dual Point Power
E
=
Dual Point Power
w/Convenience Outlet
F
=
65 SCCR Electrical Rating
w/Non-Fused Disconnect
G
=
65 SCCR Electrical Rating
w/Fused Disconnect
H
=
65 KAIC Electrical Rating
w/Non-Fused Disconnect
J
=
65 KAIC Electrical Rating
w/Fused Disconnect
K
=
65 KAIC Non-Fused
w/Convenience Outlet
L
=
65 KAIC Fused
w/Convenience Outlet
M =
65 SCCR Non-Fused
w/Convenience Outlet
10
Digit 37 — Air Flow Monitoring
0
=
No Airflow Monitoring
1
=
Airflow Monitoring—IFM
Piezo Ring
2
=
Airflow Monitoring—PE
Piezo Ring
3
=
Airflow Monitoring—Outdoor Air
with Display and IFM
w/Piezo Ring
4
=
Airflow Monitoring—IFM
Piezo Ring and PE Piezo Ring
5
=
Airflow Monitoring—Outdoor Air
Monitoring w/Display Supply Air
and Exhaust Air w/Piezo Rings
Digit 38 — Accessories
0
=
No Options
A
=
Hailguards
B
=
LED Service Light
C
=
Hailguards and LED Service
Light
D
=
LED Service Light in
Exhaust Fan Section
E
=
LED Service Light in Supply
and Exhaust Fan Section
F
=
Hailguards and LED Service
Light in Exhaust Fan Section
G
=
Hailguards and LED Service
Light in Supply and
Exhaust Fan Section
Digit 39 — Altitude
0
=
Sea Level to 1,000 Feet
1
=
1,001 to 2,000 Feet
2
=
2,001 to 3,000 Feet
3
=
3,001 to 4,000 Feet
4
=
4,001 to 5,000 Feet
5
=
5,001 to 6,000 Feet
6
=
6,001 to 7,000 Feet
7
=
Above 7,000 Feet