12.1.7.1
Wire Stripping and Connection Requirement
Wire stripping
No loose strand
when inserted
RISK OF FIRE
JOINING OF WIRES M AY CAUSE
WARNING
OVERHE ATING AND FIRE.
Do not joint wires
OR
12.1.8
Installation of Decorative Panel
The decorative panel has its installation direction. Confirm the direction by displaying the piping side.
1
Remove the air inlet grille by moving the catchers to center.
2
Fitting the decorative panel
Temporarily secure the fixing screws
o
(3 pcs.) before fitting the decorative
panel. (For temporarily securing the front
grille.)
Place decorative panel on the screws
o
(3 pcs.) before fitting, move decorative
panel as illustrated and tighten all the
screws (4 pcs.).
CAUTION
Check before hand the height from the ceiling to
the unit.
The front grille fitting direction is determined by
the unit direction.
Only use the screws with the length of 35mm
which is provided, to fix the decorative panel.
Do not use other screw which is longer it may
cause damage to the drain-pan and other
components.
Indoor/outdoor
connection
terminal
board
5 mm
or more
(gap between wires)
OR
Catcher
Air inlet grill
Decorative panel
Conductor
Conductor
fully inserted
over inserted
ACCEPT
PROHIBITED
* Hang the hinge on the hole of
decorative panel. (The direction of
the installation is free.)
Decorative
Panel moving
direction
Front grille fixing
screws (4 pcs.)
43
Conductor not
fully inserted
PROHIBITED
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to
national wiring rules.
Hinge
Air inlet grill
Securing the tentative
fixing screw
Approx. 20mm
Tighten this
screw first
after hanging the
grille frame
Piping
direction