Technical Data; Cool Mode Performance Data - Panasonic CS-Z25UB4EAW Service Manual

Hide thumbs Also See for CS-Z25UB4EAW:
Table of Contents

Advertisement

20. Technical Data

Technical data provided are based on the air conditioner running under free frequency.

20.1 Cool Mode Performance Data

Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C Voltage: 230V
20.1.1
CS-Z25UB4EAW CU-Z25UBEA
Indoor (°C)
-10
DB
WB
TC
SHC
IP
19.0 3208 2206 435 3003 2800 396 2973 2785 399 3008 2904 383 3331 3085 333 2929 2754 436 2500 2462 550
27
22.0 3252 2227 387 3217 2173 425 3254 2213 416 3310 2246 390 3674 2483 324 3208 2206 435 2897 2046 560
15.7 2696 2642 409 2579 2528 445 2654 2601 420 2562 2511 460 2504 2319 333 2412 2268 438 2405 2369 552
23
18.4 2470 2024 264 2892 2223 435 2919 2255 429 3005 2300 397 2838 2217 248 2543 1991 344 2526 1970 558
13.3 2073 2031 210 2080 2039 268 1956 1916 306 2089 2047 270 2166 2123 233 1768 1367 431 1741 1715 523
20
15.8 2546 2124 463 2572 1977 486 2669 2184 426 2563 2117 457 2735 2219 283 2163 1505 402 2085 1473 524
(Dry bulb value based on 46% humidity)
20.1.2
CS-Z35UB4EAW CU-Z35UBEA
Indoor (°C)
-10
DB
WB
TC
SHC
IP
19.0 4336 2540 698 4060 3225 635 4018 3207 640 4066 3344 615 4504 3552 534 3959 3172 700 3500 2937 900
27
22.0 4396 2565 621 4350 2502 682 4399 2548 668 4475 2587 626 4966 2859 520 4336 2540 698 3916 2356 899
15.7 3645 3205 656 3487 3094 713 3588 3164 674 3463 3100 737 3385 2670 534 3260 2612 702 3251 2728 886
23
18.4 3339 2330 423 3909 2560 698 3946 2597 689 4062 2648 637 3837 2553 398 3438 2292 552 3415 2269 896
13.3 2802 2731 336 2812 2779 430 2644 2591 491 2824 2790 433 2928 2796 374 2391 1574 691 2354 1975 838
20
15.8 3442 2446 742 3476 2276 780 3608 2515 684 3465 2438 733 3697 2555 455 2924 1733 644 2819 1696 840
(Dry bulb value based on 46% humidity)
20.1.3
CS-Z50UB4EAW CU-Z50UBEA
Indoor (°C)
-10
DB
WB
TC
SHC
IP
19.0 6257 3191 1194 5858 4052 1087 5798 4030 1096 5867 4202 1053 6498 4463 914 5713 3985 1198 5000 3690 1540
27
22.0 6343 3222 1063 6276 3143 1167 6347 3202 1142 6456 3250 1072 7166 3592 890 6257 3191 1194 5650 2961 1538
15.7 5259 4027 1122 5031 3888 1220 5177 3976 1153 4997 3895 1262 4884 3355 914 4704 3281 1201 4691 3427 1516
23
18.4 4818 2928 724 5640 3216 1194 5694 3262 1179 5861 3327 1091 5536 3208 681 4960 2880 944 4928 2851 1533
13.3 4043 3431 576 4057 3491 736 3814 3386 840 4075 3505 741 4225 3513 640 3449 1978 1182 3396 2481 1435
20
15.8 4966 3074 1270 5016 2860 1334 5206 3160 1170 5000 3063 1255 5335 3210 778 4218 2178 1103 4067 2131 1438
(Dry bulb value based on 46% humidity)
-7
0
TC
SHC
IP
TC
SHC
-7
0
TC
SHC
IP
TC
SHC
-7
0
TC
SHC
IP
TC
SHC
Outdoor DB (°C)
5
IP
TC
SHC
IP
TC
Outdoor DB (°C)
5
IP
TC
SHC
IP
TC
Outdoor DB (°C)
5
IP
TC
SHC
IP
TC
129
16
25
SHC
IP
TC
SHC
IP
16
25
SHC
IP
TC
SHC
IP
16
25
SHC
IP
TC
SHC
IP
35
TC
SHC
IP
35
TC
SHC
IP
35
TC
SHC
IP