Alarm 1 Menu; Figure 3.8 Flow Chart For Alarm 1 - Omega I Series User Manual

Temperature & process simplified menu
Hide thumbs Also See for I Series:
Table of Contents

Advertisement

3.2.8 Alarm 1 Menu

ENTER ALARM 1 MENU:
Press a
Press d
Press a
Press d
ALARM 1 LATCH SUBMENU:
Press d
Press d
Latch Enabled: Alarm remains "latched" until reset. To reset already latched
alarm, select Alarm Latch Enable and press Max twice (i.e. Disable and then go
back to Latch) or from a Run Mode, push d twice to put the monitor in Standby
Mode and then push d one more time to return to the Run Mode.
Latch Disabled: Alarm remains latched only as long as the alarm condition is true.
ACTIVE SUBMENU:
Press d
Press d
DEADBAND SUBMENU:
Press d
Press d
Figure 3.8 Flow Chart for Alarm 1 Menu
1) Press a, if necessary, until CNFG prompt appears.
2) Display advances to INPT Input Menu.
3) Press a, if necessary, until display advances to ALR1 Alarm 1
Menu.
4) Display advances to LTCH Latch.
5) Display flashes previous selection. Press b to ENBL Enable
or DSBL Disable.
6) Display shows STRD stored message momentarily and then
advances to AçTV only, if it was changed, otherwise press a to
advance to AçTV Active Submenu.
7) Display flashes previous selection. Press b to ABoV Above,
or BELo Below.
8) Display shows STRD stored message momentarily and then
advances to DEAD Deadband.
9) Display shows 020.0 Deadband value that can be changed
by pressing b or c .
10) Display shows STRD stored message momentarily and then
advances to ALR2 Alarm 2.
28